Who is this for?

Required to follow VFC & CDC requirements specifically

  • Probe in glycol
  • CDC/VFC compliant with 3 year NIST certificate
  • GDP/GMP compliant
  • Frozen to refrigerated monitoring

Required to follow GDP & GMP requirements specifically

  • Ultra-low RTD probe (no glycol bottle)
  • GDP/GMP compliant
  • Ultra-low dry ice to refrigerated monitoring

Required to follow GDP & GMP requirements specifically

  • Probe only (no glycol bottle)
  • GDP/GMP compliant
  • Frozen to ambient monitoring

Required to follow GDP & GMP requirements specifically

  • Probe in glycol
  • GDP/GMP compliant
  • Frozen to ambient monitoring

Required to follow GDP & GMP requirements specifically

  • Internal temp and humidity sensor only (No probe)
  • GDP/GMP compliant
  • Refrigerated to ambient monitoring
  • Humidity monitoring

Required to follow GDP & GMP requirements specifically

  • Internal sensor only (No probe)
  • GDP/GMP compliant
  • Refrigerated to ambient monitoring
What does it monitor?

Temperature with probe and glycol bottle and ambient room temperature

Ultra low temperature with probe only and ambient room temperature

Temperature with probe only and ambient room temperature

Temperature with probe and glycol bottle and ambient room temperature

Ambient Temperature and Relative Humidity

Ambient Room Temperature

NIST Calibration

One point NIST calibration - probe only

Two point NIST calibration - Probe only

One point NIST calibration - Probe and internal ambient sensor

One point NIST calibration - Probe and internal ambient sensor

Two point NIST calibration - Internal ambient sensor only, temp & humidity (2 points each)

One point NIST calibration - Internal ambient sensor only

NIST Expiration

3 year NIST certificate - As recommended by VFC/CDC

1 year NIST certificate - As recommended by GDP/GMP

1 year NIST certificate - As recommended by GDP/GMP

1 year NIST certificate - As recommended by GDP/GMP

1 year NIST certificate - As recommended by GDP/GMP

1 year NIST certificate - As recommended by GDP/GMP

NIST Points

Probe: 5.0°C (41.0°F)

Probe Point 1: -70.0°C (-94.0°F)

Probe Point 2: 5.0°C (41.0°F)

Probe: 5.0°C (41.0°F)

Internal Sensor: 25.0°C (77.0°F)

Probe: 5.0°C (41.0°F)

Internal Sensor: 25.0°C (77.0°F)

Int. Sensor Point 1: 0°C (32.0°F)

Int. Sensor Point 2: 40.0°C (104.0°F)

Humidity Point 1: 35.0% @ 25.0°C

Humidity Point 2: 75.0% @ 25.0°C

Internal Sensor: 25.0°C (77.0°F)

Compliance Marks

Image removed. Image removed. Image removed. Image removed.

Image removed. Image removed. Image removed. Image removed.

Image removed. Image removed. Image removed. Image removed.

Image removed. Image removed. Image removed. Image removed.

Image removed. Image removed. Image removed.

Image removed. Image removed. Image removed. Image removed.

 

Passed RTCA DO160G, part 21H

Passed RTCA DO160G, part 21H

Passed RTCA DO160G, part 21H

Passed RTCA DO160G, part 21H

N/A

Passed RTCA DO160G, part 21H

External Temperature Probe
Range

-40° to 100°C (-40° to 212°F)

-95° to 50°C (-139° to 122°F)

-40° to 100°C (-40° to 212°F)

N/A

N/A

N/A

Accuracy

±1.0°C from -40° to -25°C (±1.8°F from -40° to -13°F)

±0.5°C from -25° to 80°C (±0.9°F from -13° to 176°F)

±1.0°C from 80° to 100°C (±1.8°F from 176° to 212°F)

±1.5°C from -95° to -40°C (±2.7°F from -139° to -40°F)

±1.0°C from -40° to -10°C (±1.8°F from -40° to 14°F)

±0.5°C from -10° to 50°C (±0.9°F from -14° to 122°F)

±1.0°C from -40° to -25°C (±1.8°F from -40° to -13°F)

±0.5°C from -25° to 80°C (±0.9°F from -13° to 176°F)

±1.0°C from 80° to 100°C (±1.8°F from 176° to 212°F)

±1.0°C from -40° to -25°C (±1.8°F from -40° to -13°F)

±0.5°C from -25° to 80°C (±0.9°F from -13° to 176°F)

±1.0°C from 80° to 100°C (±1.8°F from 176° to 212°F)

N/A

N/A

Resolution

0.024°C at 25°C (0.04°F at 77°F)

0.05°C at 25°C (0.09°F at 77°F)

0.024°C at 25°C (0.04°F at 77°F)

0.024°C at 25°C (0.04°F at 77°F)

N/A

N/A

NIST Calibration

Single point NIST calibration, probe only

Two-point NIST calibration, probe only

Single point NIST calibration, probe and logger body

CX40x-Txx and CX402-BxM: Single point NIST calibration, probe and logger body

CX40x-VFCxxx: Single point NIST calibration, probe only

CX403: Single point NIST calibration

N/A

N/A

Cable Length

2 or 4 meter (6.56 or 13.12 feet) flat ribbon cable

1.5 m (4.92 ft)

2 or 4 meter (6.56 or 13.12 feet) flat ribbon cable

2 or 4 meter (6.56 or 13.12 feet) flat ribbon cable

N/A

N/A

Probe Dimensions

Food-grade stainless steel probe with pointed tip, 53.34 mm (2.1 inches) long, 3.18 mm (0.125 inches) diameter

Food-grade stainless steel probe with blunt tip, 31.75 mm (1.25 inches) long, 4.78 mm (0.188 inches) diameter

Food-grade stainless steel probe with pointed tip, 53.34 mm (2.1 inches) long, 3.18 mm (0.125 inches) diameter

Food-grade stainless steel probe with pointed tip, 53.34 mm (2.1 inches) long, 3.18 mm (0.125 inches) diameter

N/A

N/A

Temperature Sensor
Range

-30° to 70°C (-22° to 158°F)

-30° to 70°C (-22° to 158°F)

-30° to 70°C (-22° to 158°F)

-30° to 70°C (-22° to 158°F)

-30° to 70°C (-22° to 158°F)

-30° to 70°C (-22° to 158°F)

Accuracy

±1.0°C from -30° to -22°C (±1.8°F from -22° to -8°F)

±0.5°C from -22° to 50°C (±0.9°F from -8° to 122°F)

±1.0°C from 50° to 70°C (±1.8°F from 122° to 158°F)

±0.5°C from -15° to 70°C (±0.9°F from 5° to 158°F)

±1.0°C from -30° to -15°C (±1.8°F from -22° to 5°F)

±0.5°C from -15° to 70°C (±0.9°F from 5° to 158°F)

±1.0°C from -30° to -15°C (±1.8°F from -22° to 5°F)

±0.5°C from -15° to 70°C (±0.9°F from 5° to 158°F)

±1.0°C from -30° to -15°C (±1.8°F from -22° to 5°F)

±0.5°C from -30° to 70°C (±0.9°F from -22° to 158°F)

±0.5°C from -15° to 70°C (±0.9°F from 5° to 158°F)

±1.0°C from -30° to -15°C (±1.8°F from -22° to 5°F)

Resolution

0.024°C at 25°C (0.04°F at 77°F)

0.024°C at 25°C (0.04°F at 77°F)

0.024°C at 25°C (0.04°F at 77°F)

0.024°C at 25°C (0.04°F at 77°F)

0.024°C at 25°C (0.04°F at 77°F)

0.024°C at 25°C (0.04°F at 77°F)

RH Sensor
Range

N/A

N/A

N/A

N/A

0 to 95% (non-condensing)

N/A

Accuracy

N/A

N/A

N/A

N/A

±3% from 0% to 90% and ±3.5% from greater than 90% typical at 25°C (77°F)

N/A

Resolution

N/A

N/A

N/A

N/A

0.01%

N/A

Logger
Logger Operating Range

-30° to 70°C, 0 to 95% RH (non-condensing) (-22° to 158°F, 0 to 95% RH (non-condensing))

-30° to 70°C, 0 to 95% RH (non-condensing) (-22° to 158°F, 0 to 95% RH (non-condensing))

-30° to 70°C, 0 to 95% RH (non-condensing) (-22° to 158°F, 0 to 95% RH (non-condensing))

-30° to 70°C, 0 to 95% RH (non-condensing) (-22° to 158°F, 0 to 95% RH (non-condensing))

-30° to 70°C, 0 to 95% RH (non-condensing) (-22° to 158°F, 0 to 95% RH (non-condensing))

-30° to 70°C (non-condensing)

Environmental Rating

IP54

IP54

IP54

IP54

IP54

IP54

Logging Rate

1 second to 18 hours

1 second to 18 hours

1 second to 18 hours

1 second to 18 hours

1 second to 18 hours

1 second to 18 hours

Transmission Range

Approximately 30.5 m (100 ft) line-of-sight

Approximately 30.5 m (100 ft) line-of-sight

Approximately 30.5 m (100 ft) line-of-sight

Approximately 30.5 m (100 ft) line-of-sight

Approximately 30.5 m (100 ft) line-of-sight

Approximately 30.5 m (100 ft) line-of-sight

Memory

128 KB (84,650 measurements, maximum)

128 KB (75,245 total measurements or 37,622 probe & internal paired measurements)

128 KB (84,650 measurements, maximum)

128 KB (84,650 measurements, maximum)

178 KB (103,400 total measurements or 51,700 temp & RH paired measurements)

128 KB (84,650 measurements, maximum)

Full Memory Download Time

Approximately 60 seconds; may take longer the farther the device is from the logger

Approximately 60 seconds; may take longer the farther the device is from the logger

Approximately 60 seconds; may take longer the farther the device is from the logger

Approximately 60 seconds; may take longer the farther the device is from the logger

Approximately 60 seconds; may take longer the farther the device is from the logger

Approximately 60 seconds; may take longer the farther the device is from the logger

LCD

LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range

LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range

LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range

LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range

LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range

LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range

Battery Type

Two AAA 1.5 V alkaline or lithium batteries, user replaceable

Two AAA 1.5 V alkaline or lithium batteries, user replaceable

Two AAA 1.5 V alkaline or lithium batteries, user replaceable

Two AAA 1.5 V alkaline or lithium batteries, user replaceable

Two AAA 1.5 V alkaline or lithium batteries, user replaceable

Two AAA 1.5 V alkaline or lithium batteries, user replaceable

Battery Life

1 year, typical with logging interval of 1 minute. Faster logging intervals, remaining connected with the InTemp app, excessive report generation, numerous audible alarms, and paging all impact battery life.

1 year, typical with logging interval of 1 minute. Faster logging intervals, remaining connected with the app, excessive report generation, numerous audible alarms, and paging all impact battery life.

1 year, typical with logging interval of 1 minute. Faster logging intervals, remaining connected with the InTemp app, excessive report generation, numerous audible alarms, and paging all impact battery life.

1 year, typical with logging interval of 1 minute. Faster logging intervals, remaining connected with the InTemp app, excessive report generation, numerous audible alarms, and paging all impact battery life.

1 year, typical with logging interval of 1 minute. Faster logging intervals, remaining connected with the InTemp app, excessive report generation, numerous audible alarms, and paging all impact battery life.

1 year, typical with logging interval of 1 minute. Faster logging intervals, remaining connected with the InTemp app, excessive report generation, numerous audible alarms, and paging all impact battery life.

Wireless Data Standard

Bluetooth Low Energy (Bluetooth Smart)

Bluetooth Low Energy (Bluetooth Smart)

Bluetooth Low Energy (Bluetooth Smart)

Bluetooth Low Energy (Bluetooth Smart)

Bluetooth Low Energy (Bluetooth Smart)

Bluetooth Low Energy (Bluetooth Smart)

Radio Power

1 mW (0 dBm)

1 mW (0 dBm)

1 mW (0 dBm)

1 mW (0 dBm)

1 mW (0 dBm)

1 mW (0 dBm)

Dimensions

9.4 x 4.5 x 2.59 cm (3.7 x 1.77 x 1.02 inches)

9.4 x 4.5 x 2.59 cm (3.7 x 1.77 x 1.02 inches)

9.4 x 4.5 x 2.59 cm (3.7 x 1.77 x 1.02 inches)

9.4 x 4.5 x 2.59 cm (3.7 x 1.77 x 1.02 inches)

9.4 x 5.6 x 2.59 cm (3.7 x 2.21 x 1.02 inches)

9.4 x 4.5 x 2.59 cm (3.7 x 1.77 x 1.02 inches)