Skip to main content
Image
A LI-COR Brand white logo

Distributors

HOBO Main Navigation

  • Products
    Learn More
    • Multiparameter Water Quality Loggers
    • Indoor Wireless Sensor Network
    • Outdoor/Ag Wireless Sensor Network
    • Water Level Wireless Sensor Network
    • Weather Stations
    • Temperature/Relative Humidity
    • Evapotranspiration
    • Light
    • Energy
    • Soil Conditions
    • Occupancy/Runtime
    • Water Level
    • Water Quality
    • Water Temperature
    By measurement
    • Water Temperature
    • Water Level
    • Dissolved Oxygen (DO)
    • Conductivity/Temp/Depth (CTD)
    • Temperature/Relative Humidity
    • Soil Moisture
    • Ocean Current
    • Shop all measurements
    By environment
    • Indoor
    • Outdoor
    • Underwater
    • Shop all environments
    By product type
    • Data Loggers
    • Sensors and Modules
    • Solution Kits
    • Software
    • Accessories
    • Shop LI-COR Products
    • Shop all product types
    Shop all Data Loggers
  • Applications
    Environmental Research & Protection
    • Climate Monitoring
    • Environmental Compliance
    • Renewable Energy
    • Green Space Monitoring
    • Ecology
    Water Resource Management
    • Aquatic Ecology
    • Water Quality & Compliance
    • Hydrology & Groundwater Monitoring
    • Watershed Management
    • Wetland & Stormwater Management
    • Dam Management
    Building Performance
    • Data Centers
    • HVAC/R Monitoring
    • Energy Monitoring
    • Indoor Environment
    • Museum & Preservation
    • Shipping & Storage
    • Construction Compliance
    Agricultural Monitoring
    • Agricultural Research
    • Irrigation & Water Management
    • Crop Production Monitoring
    • Orchard & Vineyard Monitoring
    • Disease & Pest Management
    InTemp Cold Chain
    • Healthcare Product & Vaccine Storage
    • Life Science Shipping & Logistics
    Software
  • Support
    Help Center
    • Getting Started
    • Software
    • Troubleshooting & Maintenance
    • Tune-up & Repair Services
    • SEE ALL
    Resource Center
    • Educational Resources
    • What is a data logger?
    • Webinars On-Demand
    • Use Cases
    • Videos
    • White Papers
    • SEE ALL
  • Who We Are
    Explore HOBO
    • What is a data logger?
    • Blog
    • Press Releases & News
    • HOBO Ambassadors
    Events
    • Webinars
    • Tradeshows
    Careers
    • Why Onset
    • Job Opportunities
    About Onset
    • About Us
    • Partners
    • Contact Us

Resources

Breadcrumb
  • Home
  • Resources

Enter your search terms below:

Filters

Clear all

Applications

  • Agricultural Monitoring
    • All (171)
    • Agricultural Research (36)
    • Crop Production (29)
    • Disease and Pest (10)
    • Irrigation & Water (60)
    • Orchard & Vineyard (27)
  • Building Performance
    • All (214)
    • Construction Compliance (26)
    • Data Center Monitoring (2)
    • Energy Monitoring (69)
    • HVAC/R Monitoring Systems for Indoor Environmental Quality (IAQ & IEQ) (38)
    • Indoor Environment (63)
    • Museum & Preservation Monitoring (24)
    • Shipping & Storage Monitoring (22)
  • Environmental Research & Protection
    • All (179)
    • Climate (49)
    • Ecology (37)
    • Environmental Compliance (24)
    • Green Space (24)
    • Renewable Energy (18)
  • Water Resource Management
    • All (228)
    • Aquatic Ecology (79)
    • Dam Management (37)
    • Hydrology & Groundwater Monitoring (55)
    • Water Quality & Compliance (55)
    • Watershed Management (55)
    • Wetland & Stormwater (50)

Language

  • English (1218)
  • German (90)
  • Japanese (48)
  • Korean (16)
  • Portuguese (2)
  • Spanish (16)

Resource Type

  • Application Story (98)
  • Catalog (1)
  • Contest (1)
  • Documentation (472)
  • How-To Videos (111)
  • Informational Page (3)
  • Podcast (38)
  • Product Guide (1)
  • Product Overview Videos (26)
  • Self-Guided Training (15)
  • Tech Note (290)
  • Use Case (29)
  • Webinar (141)
  • White Paper (21)

Topic

  • Getting Started (380)
  • Software (155)
  • Troubleshooting & Maintenance (139)
1346 results found

The effects of electroshock fishing on underwater loggers

Although we have not tested this, we have run into incidents in the past where customers have left data loggers in this situation and have not had a problem. On the other hand, we have also had customers whose data loggers stopped recording. It is a gamble and strictly up to you. We do suggest that you pull the data loggers up to be on the safe side, or at least check them after to make sure that they are still recording.
Read tech note

Cleaning Optic StowAway/StowAway TidbiT data loggers

Do not use any type of chemical on an Optic or TidbiT data logger! You can wash the data logger with a mild soap and warm water solution. If the data logger has a mineral or algae build-up that will not come clean, do not scrape it off. Instead, use a plastic polish, such as Novice.
Read tech note

Logger power failure and data loss

The data is stored on non-volatile EEPROM. For data loggers with external batteries: change batteries and offload data, then relaunch normally. For data loggers with internal batteries: as long as the EEPROM has not been damaged, the data can be retrieved by Onset. Please contact the place of purchase for a return authorization number and request data back service.
Read tech note

Optic logger communication problems

All Users: HOBO Optic data loggers must be inserted into the Base Station (or Shuttle) using the appropriate coupler for that logger in order for the computer to detect them. Note: HOBOware will not detect the Base Station alone as an attached USB device. Check to make sure that the coupler is positioned properly and the magnet end is closest to the data logger, not the Base Station or the Optic Shuttle.
Read tech note

Rapid battery consumption (outdoor loggers)

All Users: Check both the logging and the sampling interval to make sure they are greater than one-minute intervals. For example, with a sampling interval of one second, the HOBO logger is constantly on and there is a constant drain to the batteries. If your application calls for such an interval, you may need to replace the batteries more frequently
Read tech note

Maximum sensor cable length

The entire network (all sensors combined) cannot exceed 100 meters. As long as your total cable length is below this, it does not matter how you designate the individual cable lengths. It is important to insure that the connections are weatherproof.
Read tech note

USB popup errors on Windows XP

Open HOBOWare, plug the logger back in, then click on Start->Settings->Control Panel->System. Click on Hardware->Device Manager and look for the logger listed under: Other Devices or Human Interface Devices — there could be a minus sign beside one of the categories or a yellow exclamation point through the device. The description listed should indicate if it is a HOBO or not. If it is not a HOBO, do not uninstall it, as it may be another USB device. Delete the "other device," then unplug the logger, wait 15 seconds, and plug it back in. Follow the onscreen instructions from there.
Read tech note

Event data logging vs State data logging

A HOBO Event data logger records the opening of the contacts only. It does not record the closing. A HOBO State data logger records changes in the state - both the opening and closing of the switch, (door open/close, light on/off, etc.). Event data will accumulate over time and totalize whereas state data will indicate a high or low position. Some HOBO series support both state and event data logging.
Read tech note

Light on/off data loggers recording more states than are actually occurring

If you are monitoring fluorescent lights, part of what you are seeing may be due to a fairly common attribute of fluorescent lights. When the filaments of a fluorescent lamp and the gas inside the lamp are not up to the normal running temperature (normally the first few minutes after startup), they are likely to flicker a bit.
Read tech note

Error #11 (Either the logger or the data file has been damaged) when downloading files from H09-002-08 Shuttle to computer

It is important that H09-002-08 HOBO Shuttle users check the status of the Shuttle's battery prior to downloading data from a logger.

Read tech note

Pagination

  • First page «
  • Previous page ‹
  • …
  • Page 121
  • Page 122
  • Current page 123
  • Page 124
  • Page 125
  • Page 126
  • …
  • Next page ›
  • Last page »
Image
A LI-COR Brand white logo

HOBO Primary Footer menu

  • Careers
  • Legal
  • Privacy Policy
  • Distributors
  • Catalog
  • LI-COR

HOBO Secondary Footer Menu

  • Contact Us
  • 1-508-759-9500

Onset®, HOBO®, InTemp®, and all other names of Onset products referenced herein are trademarks or registered trademarks of Onset Computer Corporation. ®Onset Computer Corporation. All rights reserved.