Part Number -

T-WNB-3Y-480

WattNode 480 VAC 3-phase Wye kWh Transducer Sensor

Discontinued

Effective immediately Onset no longer supplies the T-WNB-3Y-480 WattNode 480 VAC 3-phase Wye kWh Transducer. The recommended upgrade is our T-WNB-3D-480 WattNode 480 VAC 3-phase Delta kWh Transducer. Click here to view the T-WNB-3D-480 WattNode 480 VAC 3-phase Delta kWh Transducer.
Product upgrade options
3-phase transducer sensor

T-WNB-3D-480

WattNode 480 VAC 3-phase Delta/Wye kWh Transducer Sensor

$395.00 USD
View product
Overview

Effective immediately Onset no longer supplies the T-WNB-3Y-480 WattNode 480 VAC 3-phase Wye kWh Transducer. The recommended upgrade is our T-WNB-3D-480 WattNode 480 VAC 3-phase Delta kWh Transducer.

Click here to view the T-WNB-3D-480 WattNode 480 VAC 3-phase Delta kWh Transducer.

Specifications

Operating: voltage range: ±20% of nominal

Frequency: 60 Hz

CT input: 0-0.5 VAC operating, 3 VAC maximum

Connectors: UL, CSA recognized, detachable screw terminals (14 AWG), 600V

Operating temp range: -30 to 60°C (-22 to 140°F)

Operating humidity range: 0 to 90% RH, non-condensing

Dimensions: 8.5 cm x 14.3 cm x 3.8 cm (3.3 in. x 5.6 in. x 1.5 in.)

Weight: 295 g (10.4 oz.)

Number of data channels: 2

For complete device specifications please visit Continental Control Systems LLC

Wye Configuration ranges: 277, 480 Volts AC
3 Phase 4 Wire 277V/480V
Accuracy: ±0.45% of reading + 0.05% FS through 25th harmonic
(dependent on CT used and line variation accuracy could be 1.5% to 4% of reading)
Compatible items

Sensors

5 AMP Mini Split-core AC Current Transformer Sensor
$59.00 USD
20 AMP Mini Split-core AC Current Transformer Sensor
$59.00 USD
50 AMP Mini Split-core AC Current Transformer Sensor
$59.00 USD
75 AMP Mini Split-core AC Current Transformer Sensor
$55.00 USD
Documents

WattNode Pulse User's Manual - Manufacturer Website

View View

WattNode Pulse Output kWh Transducer Connection - Instructions

View View
Recently Viewed
MagneLab 75 AMP Mini Split-core AC Current Transformer Sensor
Sensor

75 AMP Mini Split-core AC Current Transformer Sensor

A small 75 AMP split-core AC Current Transformer (CT) mounted around a current carrying wire to measure AC amperage; used with HOBO data loggers via the FlexSmart TRMS module and with kWh transducers (WattNodes) for True RMS measurement of sinusoidal and non-sinusoidal waveforms.
View product
ConLab Volt AC Transmitter Sensor
Sensor

ConLab Volt AC Transmitter Sensor

A self-powered transformer for monitoring sine wave and single-phase AC voltage; compatible with HOBO MX1100, UX120-006M, ZW series, and U series data loggers.
View product
Sensor

Veris Kilowatt Hour Transducer 1-Phase, 300 Amp Sensor

The Veris AC Kilowatt Transducer incorporates one split-core AC current sensor and two voltage leads and outputs a signal proportional to kilowatts of power (consumption). Accepting an input primary voltage of 208 to 480 Volts AC rms, this transducer requires a Pulse Input Adapter. Because these sensors tie directly into the line, they should be used only by qualified personnel. NOTE: Not recommended for use with variable frequency drives.
View product
Sensor

WattNode 208/240 VAC 1,2, or 3 Phase Wye kWh Transducer Sensor

For sub-metering, net-metering, energy management, and performance contracting applications, the WattNode 208/240 VAC 1,2, or 3 Phase Wye kWh Transducer Sensor works with Magnelab AC Current Transformers and a Pulse Input Adapter to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms.
View product