ConLab Volt AC Transmitter Sensor
Part Numbers

T-CON-ACT-150

T-CON-ACT-300

ConLab Volt AC Transmitter Sensor

$200.00 USD
A self-powered transformer for monitoring sine wave and single-phase AC voltage; compatible with HOBO MX1100, UX120-006M, ZW series, and U series data loggers.

Important Information

Refer to data logger product pages to ensure you have the proper interfaces (modules, adapter, etc.) to deploy this sensor.

Options for this product
Overview

The AC Voltage transmitter is a self-powered transformer for monitoring sine wave and single-phase AC voltage. Available in two ranges: 0 to 150 Volts AC, and 0 to 300 Volts AC.

Requirements for use with specific data loggers:

  • HOBO MX1100 series: a 4-20mA input cable (SD-MA-420)
  • HOBO U12, UX120-006M, or ZW series: a 4-20mA input cable (CABLE-4-20mA)

 

Features
  • Available in 2 ranges: 0 to 150 & 0 to 300 Volts AC
  • Requires an input cable (part # CABLE-4-20mA)
Specifications
Ranges: 0-150 and 0-300 volts RMS
Sensor accuracy: < ±0.1% of span (20% to 120% of range) ±0.25% of span (10% of range)
Over range: +20% of span
Over load: +40% of span
Frequency: 60 Hz AC
Supply: Self-powered
Output: 0–20 mA
Response time to 90%: <240 msec
Operating conditions: -20° to 70°C (-4° to 158°F); 5-95% RH, non-condensing
Housing: Plastic polycarbonate
Protection Level
Box: According to IP-50 DIN 40050
Terminals: According to IP-10 DIN 40050
Mounting: Standard 35mm DIN rail

Notes: Because these sensors tie directly into the line, they should be used only by qualified personnel.

Requirements

For U12 & H8 Loggers: Input Cable (Part # CABLE-4-20mA)
For HOBO Energy Logger: FlexSmart Analog Module (Part # S-FS-CVIA)
Compatible items

Bluetooth (BLE) Data Loggers

HOBO Temp/RH/Light/Ext-Analog Data Logger
$235.00 USD
HOBO 4-Channel Analog Data Logger
$235.00 USD

USB Data Loggers - requires external sensor(s)

HOBO 4-Channel Analog Data Logger
$220.00 USD

4-20 mA

4 to 20 mA Input
$42.00 USD
Documents

Conlab AC Voltage Transmitter (T-CON-ACT-150, T-CON-ACT-300) Connection Instructions

View View
Recently Viewed
MagneLab 75 AMP Mini Split-core AC Current Transformer Sensor
Sensor

75 AMP Mini Split-core AC Current Transformer Sensor

A small 75 AMP split-core AC Current Transformer (CT) mounted around a current carrying wire to measure AC amperage; used with HOBO data loggers via the FlexSmart TRMS module and with kWh transducers (WattNodes) for True RMS measurement of sinusoidal and non-sinusoidal waveforms.
View product
Sensor

WattNode 480 VAC 3-phase Wye kWh Transducer Sensor

Effective immediately Onset no longer supplies the T-WNB-3Y-480 WattNode 480 VAC 3-phase Wye kWh Transducer. The recommended upgrade is our T-WNB-3D-480 WattNode 480 VAC 3-phase Delta kWh Transducer. Click here to view the T-WNB-3D-480 WattNode 480 VAC 3-phase Delta kWh Transducer.
View product
Sensor

Veris Kilowatt Hour Transducer 1-Phase, 300 Amp Sensor

The Veris AC Kilowatt Transducer incorporates one split-core AC current sensor and two voltage leads and outputs a signal proportional to kilowatts of power (consumption). Accepting an input primary voltage of 208 to 480 Volts AC rms, this transducer requires a Pulse Input Adapter. Because these sensors tie directly into the line, they should be used only by qualified personnel. NOTE: Not recommended for use with variable frequency drives.
View product
Sensor

WattNode 208/240 VAC 1,2, or 3 Phase Wye kWh Transducer Sensor

For sub-metering, net-metering, energy management, and performance contracting applications, the WattNode 208/240 VAC 1,2, or 3 Phase Wye kWh Transducer Sensor works with Magnelab AC Current Transformers and a Pulse Input Adapter to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms.
View product