ZW-005
HOBO Four-Channel Data Node
1 Temp, 1 RH, 1 Analog and 1 Pulse
Discontinued
Important Information
HOBO data loggers require HOBOware software and a USB cable. (Note: A USB cable is included w/HOBOware Pro CD or USB software purchase). See compatible items below.
Compatible with
Overview
The HOBO® ZW-005 is an easy-to-deploy, 4-channel wireless temperature/relative humidity data node. It includes an external 2m temperature/relative humidity sensor probe, and features one analog port, and one pulse input port. It wirelessly transmits data in real time, reducing the costs and inconvenience associated with manual data offload.
Features
- Wirelessly transmits real-time data
- Compact size for easy deployment wherever data is needed
- Accepts a wide range of external energy and environmental sensors
- Notifies you of alarm conditions via email or text messages
- Onboard buffer memory helps prevent data loss
- Powerful HOBOware® Pro software for organizing and viewing data (included with HOBO data receiver)
A complete system requires at least one wireless HOBO data node, HOBO data receiver (ZW-RCVR), and HOBOware Pro software (included with ZW-RCVR). Depending on your system deployment, a HOBO data router (ZW-ROUTER) may be required.
Specifications
Buffer memory: 3k measurements
Sample rate: 1 min to 18 hrs
Transmission rate: 2 min and greater
Power options: AC power adapter, Battery Backup
Measurement Range
Temp: -40° to 70° C (-40° to 158° F)
RH: 0 to 100% RH
Analog channels: 0 to 2.5 Vdc; 0 to 5 Vdc (w/CABLE-ADAP5); 0 to 10 Vdc (w/ CABLE-ADAP10)
Pulse channel: (w/CABLE-2.5-STEREO)0 to 65,535 pulses per logging interval
Accuracy
Temperature: ±0.21°C from 0 to 50°C (±0.38°F from 32° to 122°F); see Plot A
RH: ±2.5% from 10%RH to 90%RH typical to a maximum of ±3.5% including hysteresis at 25˚C (77˚F); below 10%RH and above 90%RH ±5% typical
Analog channel: ± 1.544 mV plus 2% of reading typical
Operating Range
Temp: -20 to 50°C (-4 to 122°F) when battery powered, -20 to 70°C (-4 to 158°F) when line powered.
RH: 5%-95% non-condensing
Resolution
Temp: 0.02° C @ 25° C (0.04° F @ 77° F)
RH: 0.05%Analog channel: 0.6 mV
Pulse channel: 1 pulse
Response Time
Temp: 5 min. in air moving 1m/sec (3.3 ft./sec)
RH: 10 min. in air moving 1 m/sec (3.3ft/sec)
Range: Approx. 100m (300ft.) depending on obstructions or interference
Weight: 138g (4.87 oz) with batteries
Dimensions: 96.5 x 108 x 28mm (3.8 x 4.25x 1.1 in)
Radio power: 1.6 mW (2 dBm)
Wireless data standard: IEEE802.15.4 2.4 GHz band
Compatible items
4-20 mA
AC Current
AC Voltage
Air Velocity
DC Amperage
DC Voltage
Differential Pressure
Gauge Pressure
Kilowatt Hours (kWh)
Temperature
Water Flow
AC Power
Compliance Certificates
NIST Setup & Certifications
Signal Input Adapters
What's in the box
- HOBO ZW-005 Four-Channel Data Node
- External 2m temp/RH sensor probe