Skip to main content
Image
A LI-COR Brand white logo

Distributors

HOBO Main Navigation

  • Products
    Learn More
    • Multiparameter Water Quality Loggers
    • Indoor Wireless Sensor Network
    • Outdoor/Ag Wireless Sensor Network
    • Water Level Wireless Sensor Network
    • Weather Stations
    • Temperature/Relative Humidity
    • Evapotranspiration
    • Light
    • Energy
    • Soil Conditions
    • Occupancy/Runtime
    • Water Level
    • Water Quality
    • Water Temperature
    By measurement
    • Water Temperature
    • Water Level
    • Dissolved Oxygen (DO)
    • Conductivity/Temp/Depth (CTD)
    • Temperature/Relative Humidity
    • Soil Moisture
    • Ocean Current
    • Shop all measurements
    By environment
    • Indoor
    • Outdoor
    • Underwater
    • Shop all environments
    By product type
    • Data Loggers
    • Sensors and Modules
    • Solution Kits
    • Software
    • Accessories
    • Shop LI-COR Products
    • Shop all product types
    Shop all Data Loggers
  • Applications
    Environmental Research & Protection
    • Climate Monitoring
    • Environmental Compliance
    • Renewable Energy
    • Green Space Monitoring
    • Ecology
    Water Resource Management
    • Aquatic Ecology
    • Water Quality & Compliance
    • Hydrology & Groundwater Monitoring
    • Watershed Management
    • Wetland & Stormwater Management
    • Dam Management
    Building Performance
    • Data Centers
    • HVAC/R Monitoring
    • Energy Monitoring
    • Indoor Environment
    • Museum & Preservation
    • Shipping & Storage
    • Construction Compliance
    Agricultural Monitoring
    • Agricultural Research
    • Irrigation & Water Management
    • Crop Production Monitoring
    • Orchard & Vineyard Monitoring
    • Disease & Pest Management
    InTemp Cold Chain
    • Healthcare Product & Vaccine Storage
    • Life Science Shipping & Logistics
    Software
  • Support
    Help Center
    • Getting Started
    • Software
    • Troubleshooting & Maintenance
    • Tune-up & Repair Services
    • SEE ALL
    Resource Center
    • Educational Resources
    • What is a data logger?
    • Webinars On-Demand
    • Use Cases
    • Videos
    • White Papers
    • SEE ALL
  • Who We Are
    Explore HOBO
    • What is a data logger?
    • Blog
    • Press Releases & News
    • HOBO Ambassadors
    Events
    • Webinars
    • Tradeshows
    Careers
    • Why Onset
    • Job Opportunities
    About Onset
    • About Us
    • Partners
    • Contact Us

Resources

Breadcrumb
  • Home
  • Resources

Enter your search terms below:

Filters

Clear all

Applications

  • Agricultural Monitoring
    • All (62)
    • Irrigation & Water (1)
  • Building Performance (7)
  • Environmental Research & Protection (59)
  • Water Resource Management
    • All (8)
    • Hydrology & Groundwater Monitoring (1)
    • Watershed Management (1)
    • Wetland & Stormwater (1)

Language

  • English (62)

Resource Type

  • (-) Tech Note (62)

Topic

  • Getting Started (45)
  • Software (10)
  • Troubleshooting & Maintenance (38)
62 results found

U30 and excitation wiring with S-VIA-CM14 modules

Here is a wiring diagram for use with external sensors and the S-VIA-CM14s. Remember the excitation current required to power the external sensors cannot exceed 50 milliamps total. http://www.onsetcomp.com/files/U30%20VIA%20and%20S_VIA_CM14.JPG
Read tech note

SMS text messaging

Sending SMS through mobile phones is easy. If you can be reminded through email, you can now be reminded through SMS.
Read tech note

U30 Analog Inputs

This information is included in the U30 manual. See attachment. Includes hardware.
Read tech note

Data logger is shutting off prematurely

A discharge of static electricity may cause a running data logger to stop recording. Precautions should be taken to prevent this while handling the data logger. Discharges may occur when there is a charge difference between the data logger and a cable being connected to it or when a person touches an exposed jack.
Read tech note

Weather station setup

Unfortunately, we do not have installers for our weather stations. We do, however, have a series of videos along with the complete user manual to help you assemble your station.
Read tech note

How often do temperature data loggers need recalibration and/or servicing?

All sensors drift over time and they can be tested in a controlled environment to make sure that they are running within the specifications outlined in the User's Manual. You can use methods such as a simple ice bath or an environmental chamber to verify your device is operating correctly.
Read tech note

Logger power failure and data loss

The data is stored on non-volatile EEPROM. For data loggers with external batteries: change batteries and offload data, then relaunch normally. For data loggers with internal batteries: as long as the EEPROM has not been damaged, the data can be retrieved by Onset. Please contact the place of purchase for a return authorization number and request data back service.
Read tech note

Rapid battery consumption (outdoor loggers)

All Users: Check both the logging and the sampling interval to make sure they are greater than one-minute intervals. For example, with a sampling interval of one second, the HOBO logger is constantly on and there is a constant drain to the batteries. If your application calls for such an interval, you may need to replace the batteries more frequently
Read tech note

Maximum sensor cable length

The entire network (all sensors combined) cannot exceed 100 meters. As long as your total cable length is below this, it does not matter how you designate the individual cable lengths. It is important to insure that the connections are weatherproof.
Read tech note

Possibility of exposure to chemicals or chemical vapors

This is dependent on the data logger you are using and the chemical and/or concentration of the chemical to which the data logger is exposed. Many chemicals will have an adverse effect on the data loggers and/or the sensors that the loggers utilize. Contact your authorized sales representative with questions regarding specific chemical contact with the data logger that you are using.
Read tech note

Pagination

  • First page «
  • Previous page ‹
  • …
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Current page 6
  • Page 7
  • Next page ›
  • Last page »
Image
A LI-COR Brand white logo

HOBO Primary Footer menu

  • Careers
  • Legal
  • Privacy Policy
  • Distributors
  • Catalog
  • LI-COR

HOBO Secondary Footer Menu

  • Contact Us
  • 1-508-759-9500

Onset®, HOBO®, InTemp®, and all other names of Onset products referenced herein are trademarks or registered trademarks of Onset Computer Corporation. ®Onset Computer Corporation. All rights reserved.