Part Number - U23-001A
HOBO U23 Pro v2 Temperature/Relative Humidity Data Logger
$210.00 USD
A weatherproof data logger with built-in temperature and relative humidity sensors; the relative humidity sensor provides superior durability in humid environments.
Important Information
Requires HOBOware software and a USB cable. (Note: A USB cable is included w/HOBOware Pro CD or USB software purchase). HOBOware Pro is required when using the U-DTW-1 Waterproof Shuttle. See compatible items below.
Compatible with
HOBOware
Overview
A weatherproof data logger with built-in temperature and relative humidity sensors; the relative humidity sensor provides superior durability in humid environments.
Image

Features
- Weatherproof housing for use in outdoor or condensing environments
- High accuracy
- Relative humidity sensor provides fast response and superior recovery from condensing conditions
- Small-diameter external sensor versions for measurements in tight spaces
- Optic USB interface for fast and reliable download
- Compatible with HOBOware and HOBOware Pro software for logger setup and graphing & analysis (HOBOware Pro is required when using the U-DTW-1 Waterproof Shuttle)
Country of Origin
United States
Build a system
Specifications
Temperature Sensor | |
Operation Range | U23-001A internal sensor: -40 to 70°C (-40 to 158°F) U23-002A external temperature sensor: -40 to 70°C (-40 to 158°F) U23-003 and U23-004 external sensors: -40 to 100°C (-40 to 212°F), with tip and cable immersion in fresh water up to 50°C (122°F) for one year |
Accuracy | U23-001A and U23-002A: ±0.25°C from -40 to 0°C (±0.45 from -40 to 32°F), ±0.2°C from 0 to 70°C (±0.36 from 32 to 158°F) U23-003 and U23-004: ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F); see Plot A |
Resolution | U23-001A and U23-002A: 0.04°C (0.072°F) U23-003 and U23-004: 0.02°C at 25°C (0.04°F at 77°F); see Plot A |
Response Time (Typical to 90%) |
U23-001A internal sensor: 10 minutes in air moving 1 m/sec U23-002A external temperature sensor: 3 minutes, 45 seconds in air moving 1 m/sec U23-003 and U23-004 external sensors: 3 minutes in air moving 1 m/sec; 30 seconds in stirred water |
Drift | U23-001A and U23-002A: <0.01°C (0.018°F) per year U23-003 and U23-004: <0.1°C (0.18°F) per year |
Relative Humidity Sensor (U23-001A, U23-002A only) | |
Operation Range | 0 to 100% RH, -40° to 70°C (-40° to 158°F) Exposure to conditions below -20°C (-4°F) or above 95% RH may temporarily increase the maximum RH sensor error by an additional 1% |
Accuracy | ±2.5% from 10% to 90% RH typical to a maximum of ±3.5% including hysteresis at 25°C (77°F); below 10% and above 90% ±5% typical |
Resolution | 0.05% |
Response Time (Typical to 90%) |
U23-001A: 40 minutes in air moving 1 m/sec with protective cap U23-002A: 15 seconds in air moving 1 m/sec |
Drift | <1% per year typical |
Logger | |
Operation Range | -40° to 70°C (-40° to 158°F) |
Real-time Clock | ±1 minute per month 0° to 50°C (32° to 122°F) |
Battery | 1/2 AA, 3.6 Volt lithium, user-replaceable (HP-B) |
Battery Life (Typical Use) | 3 years with 1 minute or greater logging interval |
Memory (Non-Volatile) | 64K bytes memory (approx. 21,000 temperature and RH measurements) |
Materials | All models: ASA styrene polymer housing and mounting clamp; polypropylene protective cap; Buna-N o-ring(s); U23-001A, U23-002A only: ASA styrene polymer RH sensor cap; modified hydrophobic polyethersulfone membrane |
Cables | U23-001A: No cables U23-002A: One 184 cm (6 ft) PVC cable; sensor diameter 1 cm (0.38 in.) U23-003: Two 184 cm (6 ft) PVC cables; sensor diameter 0.5 cm (0.20 in.) U23-004: One 184 cm (6 ft) PVC cable; sensor diameter 0.5 cm (0.20 in.) |
Environmental Rating | Electronics housing is NEMA 6P equivalent (tolerant of brief submergence); Units with RH sensors are NEMA 4 equivalent (splash-resistant) |
Launch Modes | Immediate start; delayed start |
Logging Interval | Fixed-rate or multiple logging intervals, with up to 8 user-defined logging intervals and durations; logging intervals from 1 second to 18 hours |
Offload Modes | Offload while logging; stop and offload |
Battery Indication | Battery voltage can be viewed in status screen and optionally logged in datafile. Low battery indication in datafile. |
Weight | U23-001A: 57 g (1.5 oz); U23-002A: 118 g (3.1 oz); U23-003: 138 g (3.7 oz); U23-004: 102 g (2.7 oz) |
Dimensions | Housing measures 10.2 × 3.8 cm (4.0 × 1.5 in.) |
NIST Certificate | Temperature certificate available for additional charge |
|
The CE Marking identifies this product as complying with all relevant directives in the European Union (EU). |
Compatible items
Compliance Certificates
Data Offload - Base Stations - Shuttles - Couplers
Mounting Accessories
NIST Setup & Certifications
Solar Radiation Shields
UV Protection Caps
Batteries
Desiccants
Data Offload - Base Stations - Shuttles - Couplers
Graphing & Analysis
What's in the box
- HOBO U23-001 Pro v2 Temp/RH Data Logger
- Clamp and mounting screws
- UV protective cap
Reviews
Customers Also Bought

Data Logger
HOBO USB Micro Station Data Logger
Rugged and compact, the redesigned HOBO USB Micro Station is a weatherproof data logger for multi-channel monitoring of microclimates.

Data Logger
HOBO Temperature/RH Data Logger
A weatherproof data logger with built-in temperature and relative humidity sensors, leveraging Bluetooth for easy setup and data download.

Mounting
Solar Radiation Shield
For temperature and relative humidity measurement accuracy in locations exposed to direct or reflected sunlight; ideal for use with the HOBO MX2300, HOBO Pendant, and U-Series data loggers.

Communication
HOBO Waterproof Shuttle
Provides convenient readout and relaunching of underwater and outdoor HOBO data loggers with an Optic USB interface, and is waterproof to 20m (66ft). Can also be used as a base station.