HOBO H22 Energy Data Logger
H22-001 HOBO H22 Energy Data Logger
˂
  • H22-001 Image 1
  • H22-001 Image 2
˃
Part # H22-001

HOBO H22 Energy Data Logger

Multi-Channel Data Logger

Important Info

The H22-001 Energy Logger requires HOBOware software and part # ADAPT-SER-USB interface cables. See compatible items below.

Overview

Monitor energy and industrial equipment with this 15-channel data logger (Part # H22-001). With multiple channels, energy and facility managers can quickly and easily detect and address a variety of issues relating to HVAC, machinery, and other systems.  The HOBO H22-001 Energy Data Logger is modular and more economic than its alternatives because a toolbox full of data loggers is not necessary.

Deploy this product with a variety of pre-defined plug-and-play smart sensors to create a robust monitoring system. Compatible with HOBOware® software, researchers can conduct effective data analysis in minutes.

  • Onset's most flexible data logger records up to 15 channels of over a dozen measurements
  • Provides 12v excitation for third-party sensors
  • Pre-configured smart sensors get you started fast
  • Signal conditioning modules retain configurations until you change them, providing plug-and-play convenience for commonly used sensors
  • Flexible power options include battery operation for AC power adapter

In what environment does this data logger operate?

This data logger operates in an indoor environment.

What measurements does this data logger support?

The H22-001 data logger supports the following measurements: 4-20mA, AC Current, AC Voltage, Air Velocity, Amp Hour (Ah), Carbon Dioxide, Compressed Air Flow, DC Current, DC Voltage, Dew Point, Differential Pressure, Gauge Pressure, Kilowatt Hours (kWh), Kilowatts (kW), Power Factor (PF), Pulse Input, Relative Humidity, Temperature, Volt-Amp Reactive, Volt-Amp Reactive hour, Volt-Amps (VA), Water Flow, Watt Hours (Wh) and Watts (W)

The country of origin for this product is the United States. To see the full specifications for this product, please see our product manual found under the documentation tab if available.

Choose measurement system:


Some specifications display both measurement systems and/or refer to other similar products when mentioned.

Operating range
-20° to 50°C with alkaline batteries (-4° to 122°F with alkaline batteries)
-40° to 60°C with lithium batteries (-40° to 140°F with lithium batteries)
Sensor inputs

Three FlexSmart multi-channel modules and up to 6 Smart Sensors (which may have multiple parameters/channels)

Sensor connectors

Six RJ-12 Smart Sensor jacks plus 3 FlexSmart module slots

Communication

RS-232 via 3.5 mm serial port or/and 9-pin D-Sub connector

Dimensions
15.6 cm x 8.4 cm x 4.6 cm (6.13" x 3.31" x 1.81")
Weight
435 g with batteries (15.23 oz with batteries)
238 g without batteries (8.33 oz without batteries)
Memory

512K nonvolatile flash data storage

Memory modes

Stop when full; wrap when full

Operational indicators

Six indicators provide logging and sensor network status

Logging interval

One second to 18 hours, user-specified interval (2-second minimum for two-channel S-FS-TRMSA operation)

Sensor excitation

12 V DC at 200 mA total, with user-programmable warmup time on a per-channel basis

Battery life

One year typical use (up to 75 mA excitation with 10-minute or longer logging Interval and 1-second warmup time)

Battery type
Eight standard AA alkaline batteries included (for operating conditions -20°C to 50°C) (Eight standard AA alkaline batteries included (for operating conditions -4°F to 122°F))
Optional AA lithium batteries available for operating conditions of -40° to 60°C. (Optional AA lithium batteries available for operating conditions of -40° to 140°F.)
External power

Supports optional 13.6 V DC regulated AC Wall Adapter Connector. Internal batteries may remain installed. Alternatively, an automotive battery or 9-12 V DC regulated Wall Adapter may be used, but it is recommended to remove the internal batteries since they will discharge to the level of the external supply.

Time accuracy
0 to 2 seconds for the first data point and ±5 seconds per week at 25°C (0 to 2 seconds for the first data point and ±5 seconds per week at 77°F)
Logging mode

Immediate, timed delay, or trigger (button-push) start options; supports sampling intervals for some sensors

Data communication

Current readings while logging; read out while logging; read out when stopped

Compliance Marks

CE Compliant

    • HOBO H22-001 Energy Logger
    • Eight 1.5V alkaline batteries
    • 1 miniature slotted screwdriver
    • Blank label
    • Rubber feet

The following are associated resources for this product. In general users of this product can gain insight into its possible use by utilizing the resources below.

Informational Pages

Customers Also Bought

S-FS-CVIA

The 12-bit FlexSmart Analog Input Module for use with the H22-001 Energy Logger handles two single-ended input channels with user-configurable ranges of 0 to 20mA DC or 0 to 20 V DC which is suitable for 2.5-, 5-, and 10-volt sensors. Field wiring is 2- or 3-wire via screw terminals.

Add to Cart
Compare Product

Compare
S-FS-TRMSA

The 15-bit two-channel FlexSmart True RMS Current / Voltage Module accepts an input range of 5mV to 512mV and is compatible with 333mV FS output sensors. Field wiring is 2-wire via screw terminals.

Add to Cart
Compare Product

Compare
T-WNB-3D-240

The WattNode provides accurate measurement at low cost to meet your needs for sub-metering, net-metering, energy management, and performance contracting applications. This WattNode Delta-connection kWh Transducer works with Magnelab AC Current Transformers and a Pulse Input Adapter to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms. Because these sensors tie directly into the line, they should be used only by qualified personnel. This model supports a 3-phase Delta-connection of 208/240 VAC.

Add to Cart
Compare Product

Compare
UX120-018

A high-accuracy, easy-to-deploy data logger that measures and records the power and energy consumption of 120V plug loads from office equipment, vending machines, and other devices. 

Accurate and Rugged

This UL-certified logger provides 0.5% measurement accuracy with a measurement resolution of 1 watt, making it an ideal choice for building audits where detailed energy use data is required. The rugged housing is designed to withstand the rigors of real-world handling, providing reliable performance despite bumps, drops, and use under desks.

Add to Cart
Compare Product

Compare

Recently Viewed