Part Number - H22-001
HOBO H22 Energy Data Logger
Multi-Channel Data Logger
$430.00 USD
Monitor energy and industrial equipment with this 15-channel data logger to quickly detect and address issues relating to HVAC, machinery, and other systems.
Important Information
External sensors sold separately. Requires HOBOware software and part # ADAPT-SER-USB interface cables. See compatible items below.
Compatible with
Overview
This 15-channel data logger lets energy and facility managers monitor energy and industrial equipment to quickly and easily detect and address a variety of issues relating to HVAC, machinery, and other systems. A modular device, the HOBO H22-001 Energy Data Logger is more economical than its alternatives because it eliminates the need for a toolbox full of data loggers.
Deploying this logger with a variety of pre-defined plug-and-play smart sensors create a robust monitoring system, and it's compatible with HOBOware software, so researchers can conduct effective data analysis in minutes.
Features
- Flexible data logger records up to 15 channels of more than a dozen measurements
- Provides 12v excitation for third-party sensors
- Pre-configured Smart Sensors get you started fast
- Signal conditioning modules retain configurations until you change them, providing plug-and-play convenience for commonly used sensors
- Flexible power options include battery operation for AC power adapter
Specifications
No category
- Operating range
-
-20° to 50°C with alkaline batteries-4° to 122°F with alkaline batteries-40° to 60°C with lithium batteries-40° to 140°F with lithium batteries
- Sensor inputs
-
Three FlexSmart multi-channel modules and up to 6 Smart Sensors (which may have multiple parameters/channels)
- Sensor connectors
-
Six RJ-12 Smart Sensor jacks plus 3 FlexSmart module slots
- Communication
-
RS-232 via 3.5 mm serial port or/and 9-pin D-Sub connector
- Dimensions
-
15.6 cm x 8.4 cm x 4.6 cm6.13" x 3.31" x 1.81"
- Weight
-
435 g with batteries15.23 oz with batteries238 g without batteries8.33 oz without batteries
- Memory
-
512K nonvolatile flash data storage
- Memory modes
-
Stop when full; wrap when full
- Operational indicators
-
Six indicators provide logging and sensor network status
- Logging interval
-
One second to 18 hours, user-specified interval (2-second minimum for two-channel S-FS-TRMSA operation)
- Sensor excitation
-
12Â V DC at 200Â mA total, with user-programmable warmup time on a per-channel basis
- Battery life
-
One year typical use (up to 75Â mA excitation with 10-minute or longer logging Interval and 1-second warmup time)
- Battery type
-
Eight standard AA alkaline batteries included (for operating conditions -20°C to 50°C)Eight standard AA alkaline batteries included (for operating conditions -4°F to 122°F)Optional AA lithium batteries available for operating conditions of -40° to 60°C.Optional AA lithium batteries available for operating conditions of -40° to 140°F.
- External power
-
Supports optional 13.6 V DC regulated AC Wall Adapter Connector. Internal batteries may remain installed. Alternatively, an automotive battery or 9-12 V DC regulated Wall Adapter may be used, but it is recommended to remove the internal batteries since they will discharge to the level of the external supply.
- Time accuracy
-
0 to 2 seconds for the first data point and ±5 seconds per week at 25°C0 to 2 seconds for the first data point and ±5 seconds per week at 77°F
- Logging mode
-
Immediate, timed delay, or trigger (button-push) start options; supports sampling intervals for some sensors
- Data communication
-
Current readings while logging; read out while logging; read out when stopped
Image

Compatible items
Graphing & Analysis
4-20 mA
AC Current
AC Voltage
Air Velocity
DC Current
DC Voltage
Differential Pressure
Gauge Pressure
Kilowatt Hours (kWh)
Light Intensity
Pulse Input
Rainfall
Relative Humidity
Temperature
Water Flow
Communication Cables
AC Power
Cable Adapters - Splitter
Compliance Certificates
Mounting Accessories
What's in the box
- HOBO H22-001 Energy Logger
- Eight 1.5V alkaline batteries
- 1 miniature slotted screwdriver
- Blank label
- Rubber feet
Customers Also Bought

Sensor
FlexSmart Analog Module (2 channels) Sensor
For use with the H22 Energy Logger; handles two single-ended input channels with user-configurable ranges of 0 to 20mA DC or 0 to 20 V DC; suitable for 2.5-, 5-, and 10-volt sensors.

Sensor
FlexSmart TRMS Module (2 channels) Sensor
A 15-bit two-channel module that accepts an input range of 5mV to 512mV and is compatible with 333mV FS output sensors.

Sensor
WattNode 208/240 VAC 3-phase Delta/Wye kWh Transducer Sensor
For sub-metering, net-metering, energy management, and performance contracting applications, the WattNode 208/240 VAC 3-phase Delta/Wye kWh Transducer Sensor works with Magnelab AC Current Transformers and a Pulse Input Adapter to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms.

Data Logger
HOBO Plug Load Data Logger
A high-accuracy, easy-to-deploy data logger that measures and records the power and energy consumption of 120V plug loads by simply plugging office equipment, vending machines, and other devices into the logger