Skip to main content
Image
A LI-COR Brand white logo

Distributors

HOBO Main Navigation

  • Products
    Learn More
    • Multiparameter Water Quality Loggers
    • Indoor Wireless Sensor Network
    • Outdoor/Ag Wireless Sensor Network
    • Water Level Wireless Sensor Network
    • Weather Stations
    • Temperature/Relative Humidity
    • Evapotranspiration
    • Light
    • Energy
    • Soil Conditions
    • Occupancy/Runtime
    • Water Level
    • Water Quality
    • Water Temperature
    By measurement
    • Water Temperature
    • Water Level
    • Dissolved Oxygen (DO)
    • Conductivity/Temp/Depth (CTD)
    • Temperature/Relative Humidity
    • Soil Moisture
    • Light
    • Ocean Current
    • Shop all measurements
    By environment
    • Indoor
    • Outdoor
    • Underwater
    • Shop all environments
    By product type
    • Data Loggers
    • Sensors and Modules
    • Solution Kits
    • Software
    • Accessories
    • Shop LI-COR Products
    • Shop all product types
    Shop all Data Loggers
  • Applications
    Environmental Research & Protection
    • Climate Monitoring
    • Environmental Compliance
    • Renewable Energy
    • Green Space Monitoring
    • Ecology
    Water Resource Management
    • Aquatic Ecology
    • Water Quality & Compliance
    • Hydrology & Groundwater Monitoring
    • Watershed Management
    • Wetland & Stormwater Management
    • Dam Management
    Building Performance
    • Data Centers
    • HVAC/R Monitoring
    • Energy Monitoring
    • Indoor Environment
    • Museum & Preservation
    • Shipping & Storage
    • Construction Compliance
    Agricultural Monitoring
    • Agricultural Research
    • Irrigation & Water Management
    • Crop Production Monitoring
    • Orchard & Vineyard Monitoring
    • Disease & Pest Management
    InTemp Cold Chain
    • Healthcare Product & Vaccine Storage
    • Life Science Shipping & Logistics
    Software
  • Support
    Help Center
    • Getting Started
    • Software
    • Troubleshooting & Maintenance
    • Tune-up & Repair Services
    • SEE ALL
    Resource Center
    • Educational Resources
    • What is a data logger?
    • Webinars On-Demand
    • Use Cases
    • Videos
    • White Papers
    • SEE ALL
  • Who We Are
    Explore HOBO
    • What is a data logger?
    • Blog
    • Press Releases & News
    • HOBO Ambassadors
    Events
    • Webinars
    • Tradeshows
    Careers
    • Why Onset
    • Job Opportunities
    About Onset
    • About Us
    • Partners
    • Contact Us

Resources

Breadcrumb
  • Home
  • Resources

Enter your search terms below:

Filters

Clear all

Applications

  • Agricultural Monitoring
    • All (9)
    • Agricultural Research (1)
    • Crop Production (1)
    • Disease and Pest (1)
    • Irrigation & Water (1)
    • Orchard & Vineyard (1)
  • Building Performance
    • All (129)
    • Construction Compliance (9)
    • Energy Monitoring (39)
    • HVAC/R Monitoring Systems for Indoor Environmental Quality (IAQ & IEQ) (22)
    • Indoor Environment (19)
    • Museum & Preservation Monitoring (9)
    • Shipping & Storage Monitoring (8)
  • Environmental Research & Protection
    • All (15)
    • Climate (3)
    • Ecology (2)
    • Environmental Compliance (1)
    • Green Space (3)
    • Renewable Energy (4)
  • Water Resource Management
    • All (9)
    • Aquatic Ecology (2)
    • Dam Management (1)
    • Hydrology & Groundwater Monitoring (1)
    • Water Quality & Compliance (2)
    • Watershed Management (1)
    • Wetland & Stormwater (1)

Language

  • English (126)
  • Spanish (3)

Resource Type

  • Documentation (3)
  • How-To Videos (11)
  • Informational Page (1)
  • Podcast (19)
  • Product Overview Videos (10)
  • Self-Guided Training (4)
  • Tech Note (54)
  • Webinar (17)
  • White Paper (10)

Topic

  • (-) Getting Started (129)
  • Software (15)
  • Troubleshooting & Maintenance (28)
129 results found

T-VER-E50B2 operation

The T-VER-E50B2 Energy and Power Meter outputs three sets of pulses that are logged by the UX120-017. These pulses represent Watt-hours, Amp-hours, and VAR-hours. HOBOware software uses these pulse values to calculate AC Current, AC Voltage, kW, Power Factor, VARs, and VA. /files/14993-A-Derived-Channels.zip
Read tech note

3-phase Wattnode product comparison

Read tech note

H22-001 grounding

See attached PDF
Read tech note

Thermocouple wire material rating

Below are ratings on the material, not to be confused with measurement range. Common TC types used on HOBO data loggers: Type-J and Type-T wire is Teflon insulated and rated up to +400°F (+200°C) continuous, and +482°F (+250°C), for 24 hours Type-K wire is glass-braid insulated and rated up to +900°F (+482°C) continuous, and +1000°F (+537°C) for a short single exposure.
Read tech note

Making beaded probes on a thermocouple wire

A thermocouple is a kind of battery made by joining two dissimilar metals together where a small voltage is generated by the difference between teh metals. The voltage gnerated changes with temperature. To make a thermocouple temperature sensor out of thermocouple extenision wire, strip the insulation back a little and make an electrical connection between the two wires. The more reliable your connection, the more reliable the thermocouple. Welding is the best way to form a reliable thermocouple. A resistance welding machine (spot welder) can be used (with practice), and TIG welding works nicely too.
Read tech note

How often do temperature data loggers need recalibration and/or servicing?

All sensors drift over time and they can be tested in a controlled environment to make sure that they are running within the specifications outlined in the User's Manual. You can use methods such as a simple ice bath or an environmental chamber to verify your device is operating correctly.
Read tech note

Event data logging vs State data logging

A HOBO Event data logger records the opening of the contacts only. It does not record the closing. A HOBO State data logger records changes in the state - both the opening and closing of the switch, (door open/close, light on/off, etc.). Event data will accumulate over time and totalize whereas state data will indicate a high or low position. Some HOBO series support both state and event data logging.
Read tech note

Possibility of exposure to chemicals or chemical vapors

This is dependent on the data logger you are using and the chemical and/or concentration of the chemical to which the data logger is exposed. Many chemicals will have an adverse effect on the data loggers and/or the sensors that the loggers utilize. Contact your authorized sales representative with questions regarding specific chemical contact with the data logger that you are using.
Read tech note

Protecting data loggers from electrical discharge (ESD)

A discharge of static electricity may cause a running data logger to stop recording. Precautions should be taken to prevent this while handling the data logger. Discharges may occur when there is a charge difference between the data logger and a cable being connected to it or when a person touches an exposed jack.
Read tech note

Pagination

  • First page «
  • Previous page ‹
  • …
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Current page 13
Image
A LI-COR Brand white logo

HOBO Primary Footer menu

  • Careers
  • Legal
  • Privacy Policy
  • Distributors
  • Catalog
  • LI-COR

HOBO Secondary Footer Menu

  • Contact Us
  • 1-508-759-9500

Onset®, HOBO®, InTemp®, and all other names of Onset products referenced herein are trademarks or registered trademarks of Onset Computer Corporation. ®Onset Computer Corporation. All rights reserved.