Skip to main content
Image
A LI-COR Brand white logo

Distributors

HOBO Main Navigation

  • Products
    Learn More
    • Multiparameter Water Quality Loggers
    • Indoor Wireless Sensor Network
    • Outdoor/Ag Wireless Sensor Network
    • Water Level Wireless Sensor Network
    • Weather Stations
    • Temperature/Relative Humidity
    • Evapotranspiration
    • Light
    • Energy
    • Soil Conditions
    • Occupancy/Runtime
    • Water Level
    • Water Quality
    • Water Temperature
    By measurement
    • Water Temperature
    • Water Level
    • Dissolved Oxygen (DO)
    • Conductivity/Temp/Depth (CTD)
    • Temperature/Relative Humidity
    • Soil Moisture
    • Light
    • Ocean Current
    • Shop all measurements
    By environment
    • Indoor
    • Outdoor
    • Underwater
    • Shop all environments
    By product type
    • Data Loggers
    • Sensors and Modules
    • Solution Kits
    • Software
    • Accessories
    • Shop LI-COR Products
    • Shop all product types
    Shop all Data Loggers
  • Applications
    Environmental Research & Protection
    • Climate Monitoring
    • Environmental Compliance
    • Renewable Energy
    • Green Space Monitoring
    • Ecology
    Water Resource Management
    • Aquatic Ecology
    • Water Quality & Compliance
    • Hydrology & Groundwater Monitoring
    • Watershed Management
    • Wetland & Stormwater Management
    • Dam Management
    Building Performance
    • Data Centers
    • HVAC/R Monitoring
    • Energy Monitoring
    • Indoor Environment
    • Museum & Preservation
    • Shipping & Storage
    • Construction Compliance
    Agricultural Monitoring
    • Agricultural Research
    • Irrigation & Water Management
    • Crop Production Monitoring
    • Orchard & Vineyard Monitoring
    • Disease & Pest Management
    InTemp Cold Chain
    • Healthcare Product & Vaccine Storage
    • Life Science Shipping & Logistics
    Software
  • Support
    Help Center
    • Getting Started
    • Software
    • Troubleshooting & Maintenance
    • Tune-up & Repair Services
    • SEE ALL
    Resource Center
    • Educational Resources
    • What is a data logger?
    • Webinars On-Demand
    • Use Cases
    • Videos
    • White Papers
    • SEE ALL
  • Who We Are
    Explore HOBO
    • What is a data logger?
    • Blog
    • Press Releases & News
    • HOBO Ambassadors
    Events
    • Webinars
    • Tradeshows
    Careers
    • Why Onset
    • Job Opportunities
    About Onset
    • About Us
    • Partners
    • Contact Us

Resources

Breadcrumb
  • Home
  • Resources

Enter your search terms below:

Filters

Clear all

Applications

  • Agricultural Monitoring (7)
  • Building Performance
    • All (64)
    • Energy Monitoring (3)
  • Environmental Research & Protection (7)
  • Water Resource Management (7)

Language

  • English (64)

Resource Type

  • (-) Tech Note (64)

Topic

  • Getting Started (54)
  • Software (16)
  • Troubleshooting & Maintenance (38)
64 results found

T-VER-E50B2 operation

The T-VER-E50B2 Energy and Power Meter outputs three sets of pulses that are logged by the UX120-017. These pulses represent Watt-hours, Amp-hours, and VAR-hours. HOBOware software uses these pulse values to calculate AC Current, AC Voltage, kW, Power Factor, VARs, and VA. /files/14993-A-Derived-Channels.zip
Read tech note

3-phase Wattnode product comparison

Read tech note

Data logger is shutting off prematurely

A discharge of static electricity may cause a running data logger to stop recording. Precautions should be taken to prevent this while handling the data logger. Discharges may occur when there is a charge difference between the data logger and a cable being connected to it or when a person touches an exposed jack.
Read tech note

H22-001 grounding

See attached PDF
Read tech note

Thermocouple wire material rating

Below are ratings on the material, not to be confused with measurement range. Common TC types used on HOBO data loggers: Type-J and Type-T wire is Teflon insulated and rated up to +400°F (+200°C) continuous, and +482°F (+250°C), for 24 hours Type-K wire is glass-braid insulated and rated up to +900°F (+482°C) continuous, and +1000°F (+537°C) for a short single exposure.
Read tech note

Making beaded probes on a thermocouple wire

A thermocouple is a kind of battery made by joining two dissimilar metals together where a small voltage is generated by the difference between teh metals. The voltage gnerated changes with temperature. To make a thermocouple temperature sensor out of thermocouple extenision wire, strip the insulation back a little and make an electrical connection between the two wires. The more reliable your connection, the more reliable the thermocouple. Welding is the best way to form a reliable thermocouple. A resistance welding machine (spot welder) can be used (with practice), and TIG welding works nicely too.
Read tech note

How often do temperature data loggers need recalibration and/or servicing?

All sensors drift over time and they can be tested in a controlled environment to make sure that they are running within the specifications outlined in the User's Manual. You can use methods such as a simple ice bath or an environmental chamber to verify your device is operating correctly.
Read tech note

Logger power failure and data loss

The data is stored on non-volatile EEPROM. For data loggers with external batteries: change batteries and offload data, then relaunch normally. For data loggers with internal batteries: as long as the EEPROM has not been damaged, the data can be retrieved by Onset. Please contact the place of purchase for a return authorization number and request data back service.
Read tech note

Event data logging vs State data logging

A HOBO Event data logger records the opening of the contacts only. It does not record the closing. A HOBO State data logger records changes in the state - both the opening and closing of the switch, (door open/close, light on/off, etc.). Event data will accumulate over time and totalize whereas state data will indicate a high or low position. Some HOBO series support both state and event data logging.
Read tech note

Light on/off data loggers recording more states than are actually occurring

If you are monitoring fluorescent lights, part of what you are seeing may be due to a fairly common attribute of fluorescent lights. When the filaments of a fluorescent lamp and the gas inside the lamp are not up to the normal running temperature (normally the first few minutes after startup), they are likely to flicker a bit.
Read tech note

Pagination

  • First page «
  • Previous page ‹
  • …
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Current page 6
  • Page 7
  • Next page ›
  • Last page »
Image
A LI-COR Brand white logo

HOBO Primary Footer menu

  • Careers
  • Legal
  • Privacy Policy
  • Distributors
  • Catalog
  • LI-COR

HOBO Secondary Footer Menu

  • Contact Us
  • 1-508-759-9500

Onset®, HOBO®, InTemp®, and all other names of Onset products referenced herein are trademarks or registered trademarks of Onset Computer Corporation. ®Onset Computer Corporation. All rights reserved.