MX2309
HOBO MX2309 Temp/RH/Solar Data Logger
Measures Temperature, RH & Solar Radiation with LI-COR 200R Pyranometer
Important Information
Requires a compatible mobile device or Windows computer and the HOBOconnect app. System requirements for the app can be found at bottom of the HOBOconnect software page.
Compatible with
Overview
The MX2309 pairs research-grade sensing with wireless convenience, integrating the renowned LI-COR LI-200R pyranometer that delivers solar radiation measurements with scientific-grade accuracy (calibration uncertainty of ±3% typical).
This all-in-one device captures a comprehensive climate picture, combining an external LI-200R pyranometer (measuring total solar irradiance in the 400–1100 nm range) and built-in temperature and relative humidity sensors. This enables the calculation of critical metrics such as Accumulated Solar Radiation (MJ/ m²), Daily Light Integral (DLI of Solar, MJ/m²/day), Vapor Pressure Deficit (VPD, kPa), and Dew Point. Providing laboratory-quality measurements of solar climate conditions in an affordable, mobile logger, the rugged, battery-powered MX2309 is easily deployed and expands monitoring capabilities to an even broader range of environmental and energy applications.
IMPORTANT NOTE: For mounting, an M-PLT and 2003S Leveling Fixture are required. Mounting to poles or pipes require an M-BRK and 2003S.
Users can mount the sensor in the field, and setup and data retrieval are seamlessly simple—no cables or additional download devices needed using the free HOBOconnect app on your phone or tablet. Effortlessly configure the logger and download data via Bluetooth (up to a 100 ft range), which allows you to deploy in and download data from hard-to-reach spots.
Expand your remote monitoring by adding an MX Data Plan, which allows you to upload data to LI-COR Cloud remote software for further analysis, sharing, and more.
Features
Specifications
Temperature Sensor
-
-40 to 65 °C (-40 to 149 °F)
-
±0.2 °C (typical) within -40 to 65 °C
-
0.008°C (.014 °F)
-
<0.01°C (0.018°F) per year
Relative Humidity (RH) Sensor
-
0 to 100% RH, -40° to 65 °C (-40° to 149 °F); exposure to conditions below -20°C (-4°F) or above 95% RH may temporarily increase the maximum RH sensor error by an additional 1%
-
±2.5% from 10% to 90% (typical) to a maximum of ±3.5% including hysteresis at 25°C (77°F); below 10% RH and above 90% RH ±5% typical
-
0.01% RH
-
<1% per year typical
Global Solar Radiation Sensor
-
0 to ~1280 W/m² (full sunlight)
-
±3% typical, ± 5% maximum (LI-200R Absolute Calibration:)*
-
± 0.5 W/m²
-
0.05 W/m²
-
400–1100 nm
-
Maximum deviation of 1% up to 3,000 W m-2
-
<= 2% change over one year
-
±0.15% per ˚C maximum
-
Cosine corrected up to 82˚ angle of incidence
-
<±1% error over 360˚ at 45˚ elevation
-
No error induced from orientation
-
High stability silicon photovoltaic detector (blue enhanced)
-
Weatherproof anodized aluminum case with acrylic diffuser and stainless steel hardware. O-ring seal on the sensor base.
-
2.36 cm diameter x 3.63 cm (095” x 1.43”)
-
1.8 m
Calculated Metrics
Response Time (typical, to 90% of charge)
-
Without Solar Radiation Shield: 17 minutes in air moving 1 m/secWith RS1 Solar Radiation Shield: 24 minutes in air moving 1 m/sec
-
Without Solar Radiation Shield: 30 seconds in air moving 1 m/secWith RS1 Solar Radiation Shield: 40 seconds in air moving 1 m/sec
Logger
-
-40 to 65 °C (-40 to 149 °F)
-
0.4mW (-4 dBm)
-
Approximately 30.5 m (100 ft) line-of-sight
-
Bluetooth Low Energy (Bluetooth Smart)
-
1 second to 18 hours
-
Fixed interval (normal, statistics) or burst
-
Wrap when full or stop when full
-
Immediate, push button, date & time, or next interval
-
When memory is full, push button, date & time, or after a set logging period
-
±1 minute per month 0° to 50°C (32° to 122°F)
-
2/3 AA 3.6 Volt lithium, user replaceable
-
2 years, typical with logging interval of 1 minute and Bluetooth Always On enabled; 5 years, typical with logging interval of 1 minute and Bluetooth Always On disabled. Faster logging intervals and statistics sampling intervals, burst logging, remaining c
-
195,000 measurements, maximum
-
Approximately 4-5 minutes; may take longer the further the device is from the logger
-
Logger housing: 10.8 x 5.08 x 2.24 cm (4.25 x 2.0 x 0.88 in.)LI-190R: 2.36 cm diameter × 3.63 cm (0.93 × 1.43 in.)
-
Logger: 149 g (5.26 oz)
-
Acetal, silicone gasket, stainless steel screws
-
NEMA 6 and IP67
*: Calibrated against an Eppley Precision Spectral Pyranometer (PSP) under natural daylight conditions. Absolute uncertainty under these conditions is ± 3% typical; ± 5% maximum