Stopping your data logger

All HOBO and StowAway data loggers shut off when the memory is full (unless wrap-around is selected) or the data is downloaded to a computer. Once the data is downloaded to the computer, the data logger is in off mode and will need to be relaunched to continue data collection. If the data logger you are using is shuttle-compatible and you are downloading to a shuttle, the shuttle will automatically relaunch the data logger using the previous settings.

Data loss and recovery

There are two common reasons for data loss:

Drying a wet circuit board

If possible, remove the board from the case and the battery from the board. Dry the board completely using a hair dryer. If the board was exposed to salt water, rinse the board with fresh water and then dry the board. You may try inserting a new battery and downloading the data. If you are unable to access the data, or see any sign of corrosion or tarnishing on the board, contact the place of purchase for a return number. The data may be retrievable, and the data logger may be repairable. Charges will apply and are dependent on the amount of damage.

Possibility of exposure to chemicals or chemical vapors

This is dependent on the data logger you are using and the chemical and/or concentration of the chemical to which the data logger is exposed. Many chemicals will have an adverse effect on the data loggers and/or the sensors that the loggers utilize. Contact your authorized sales representative with questions regarding specific chemical contact with the data logger that you are using.

Rapid battery consumption (outdoor loggers)

All Users: Check both the logging and the sampling interval to make sure they are greater than one-minute intervals. For example, with a sampling interval of one second, the HOBO logger is constantly on and there is a constant drain to the batteries. If your application calls for such an interval, you may need to replace the batteries more frequently

Logger power failure and data loss

The data is stored on non-volatile EEPROM. For data loggers with external batteries: change batteries and offload data, then relaunch normally. For data loggers with internal batteries: as long as the EEPROM has not been damaged, the data can be retrieved by Onset. Please contact the place of purchase for a return authorization number and request data back service.

Rain Gauge Field Calibration Kit

The manufacturer of Onset rain buckets, Texas Electronics, offers a calibration kit that makes it easy to calibrate your rain gauges in the field.

Measure Direct Current with the HOBO RX3000 and the T-VER-H971 Transducer

To measure Direct Current using the HOBO RX3000 and the T-VER-H971 transducer, see attachment.

Trouble sharing exported HOBOlink data from an iPhone/iPad

There is a known limitation with sharing files downloaded from HOBOlink on an iPhone or iPad using Google Chrome.