Volatile Organic Compound (VOC) Sensor - T-ION-TVOC
Overview
Description & Features
Detailed Specifications
Documentation
The TVOC sensor is a fixed continuous monitor for the detection and measurement of total volatile organic compounds, which can be dangerous from both a poisoning and explosive perspective.
Requires analog port selection during U30 system configuration and use of a S-FS-CVIA when using the H22-001 logger.
When using a U12 logger or ZW series data loggers, this sensor requires a 4-20mA input cable (CABLE-4-20mA) and external power provided by an AC adapter (AC-SENS-1).
Features:
Intrinsically Safe for use in hazardous areas
Environment:
The T-ION-TVOC Sensor is for use in Indoor environments
Measurements:
The T-ION-TVOC Sensor supports the following measurements : Volatile Organic Compound
| Measurement range: selectable 0 - 10, 0 - 100, 0 - 1000 ppm (parts per million) |
| Accuracy: (0-10 and 0-100 ppm) +/- 2%; (100-1000 ppm) +/- 5% |
| Linearity: (0 - 100 ppm) > 98% |
| Input power, sensor: 5 - 28 VDC, 65 mA |
| Input power, 4-20mA loop: 8 - 35 VDC, 22 mA |
| Operating temperature range: -200C to 500C (-40F to 1220F) |
| Operating humidity range: 0 to 95% RH non-condensing |
| Response: sensor T90 < 5 sec. |
| Sensor: PID Lamp, 10.6 eV (Krypton) |
| Lamp duty cycle: selectable 5 sec. to 5 min. (1 min. std.) |
| Sampling process: diffusion |
| Output signal: 4 - 20 mA |
| Dimensions: 7.11x4.88x2,86 in (181x124x72.6 mm) |
| Weight: 2.9 lbs. (1.3 kg) |
| Display: 7 segment 4-digit LCD, 4 colors |
| Calibration: four stage |
| Ingress protection: (TVOC) - IP65; (sensor) - IP54 |
| Intrinsic safe approvals: II 2 G Eex ia IIC T4, cert # Baseefa05ATEX0277 |
Compatible Loggers
open
Standalone close
HOBO U30-NRC Weather Station Starter Kit
VIA (Primary Analog Input Adapter Option for U30 systems)
The T-ION-TVOC sensor requires a VIA (Primary Analog Input Adapter Option for U30 systems) to function with the . A VIA adapter is added to the U30 data logger during system configuration, if necessary.
HOBO U30-NRC Weather Station Starter Kit
| Qty. | 1-9 | 10-99 | 100+ | |
| $US | $1,380 | $1,311 | $1,242 |
|
New Product - Call for availability. |
VIA (Primary Analog Input Adapter Option for U30 systems)
The T-ION-TVOC sensor requires a VIA (Primary Analog Input Adapter Option for U30 systems) to function with the . A VIA adapter is added to the U30 data logger during system configuration, if necessary.
Temperature/Relative Humidity/Light/External
| Qty. | 1-9 | 10-99 | 100+ | |
| $US | $133 | $123 | $113 |
Temperature/Relative Humidity/2 External Channel
| Qty. | 1-9 | 10-99 | 100+ | |
| $US | $133 | $123 | $113 |
4-Channel External
| Qty. | 1-9 | 10-99 | 100+ | |
| $US | $108 | $100 | $92 |
4-Channel External
| Qty. | 1-9 | 10-99 | 100+ | |
| $US | $215 | $199 | $183 |
Energy Logger
| Qty. | 1-9 | 10-99 | 100+ | |
| $US | $315 | $299 | $283 |
open
Web-based Monitoring Systems close
open
Wireless Data Nodes close
4 Channel - Temp/RH Data Node
1 Temp, 1 RH, 1 Analog and 1 Pulse
| Qty. | 1-9 | 10-99 | 100+ | |
| $US | $299 | $277 | $254 |
data node – Temp/RH/2 External Channels
| Qty. | 1-9 | 10-99 | 100+ | |
| $US | $299 | $277 | $254 |
data node – 4 Analog Ports
| Qty. | 1-9 | 10-99 | 100+ | |
| $US | $219 | $203 | $186 |
4 External Channels - Data Node
External; 2 Analog and 2 Pulse
| Qty. | 1-9 | 10-99 | 100+ | |
| $US | $219 | $203 | $186 |
Your Cart
No items in cart.
-Sensor_T-ION-TVOC.jpg)