Part Number - S-FS-CVIA

FlexSmart Analog Module (2 channels) Sensor

$125.00 USD
For use with the H22 Energy Logger; handles two single-ended input channels with user-configurable ranges of 0 to 20mA DC or 0 to 20 V DC; suitable for 2.5-, 5-, and 10-volt sensors.

Overview

For use with the H22 Energy Logger, this module handles two single-ended input channels with user-configurable ranges of 0 to 20mA DC or 0 to 20 V DC, which is suitable for 2.5-, 5-, and 10-volt sensors. Field wiring is 2- or 3-wire via screw terminals.

Features

  • 2 input channels of 0-20mA and/or 0-20 VDC
  • Provides 12V sensor excitation and user-configurable warm-up

Specifications

Input channels: 2 single-ended
User-configurable ranges: 0-20mA, 0-20VDC (suitable for 2.5, 5, and 10V sensors)
Accuracy: ±0.25% FS over range selected from 50mV to FS
A/D accuracy: ±0.05%
A/D drift: 5 ppm/°C
Resolution: 12-bit
Excitation power: 12V DC @ up to 200mA switched, with up to 2-minute warm-up in 5 msec increments
Field wiring: 2- or 3-wire via screw terminals

Compatible items

USB Data Loggers - requires external sensor(s)

H22-001
$430.00 USD

Sensors

S-FS-CVIA
$125.00 USD
T-ASH-G2-100
$269.00 USD
T-ASH-G2-200
$269.00 USD
T-ASH-G2-500
$269.00 USD
T-VER-971BP-200
$289.00 USD

DC Current

T-VER-971BP-200
$289.00 USD

Gauge Pressure

T-ASH-G2-100
$269.00 USD
T-ASH-G2-200
$269.00 USD
T-ASH-G2-500
$269.00 USD

Compliance Certificates

COMPLIANCE CERT
$30.00 USD

Documents

FlexSmart Analog Module (S-FS-CVIA) Quick Start Guide (CE compliant)

View View

Customers Also Bought

Data Logger

HOBO H22 Energy Data Logger

Monitor energy and industrial equipment with this 15-channel data logger to quickly detect and address issues relating to HVAC, machinery, and other systems.
View product