HOBO U30 USB Data Logger - U30-NRC
The HOBO U30-NRC Weather Station is our most rugged data logging system that can be easily reconfigured and adapted to a wide variety of applications. Up to 15 channels of environmental data can be measured and recorded, and later analyzed with HOBOware® Pro software.
Key advantages:
- All electronics are housed within a rugged double-weatherproof, tamper-proof enclosure
- Set up is quick and easy with plug-and-play sensors
- Fast data offload via USB
- Optional analog inputs with sensor excitation
- Includes relay that can be activated on user-defined alarm conditions
Measurements:
Specifications
Normal operating range: -20°C to 40°C (-4°F to 104°F)
Extended operating range: -40 to 60°C (-40 to 140°F) - see "Rechargeable Battery service Life" for impact of operations in Extended Operating Range.
Sensor Inputs: 5 standard; option to expand to 10
Smart Sensor Compatibility: Compatible with most Onset smart sensors, except for the S-BPA, S-TMA and S-THA
Data Channels: Maximum of 15 (some sensors use more than one data channel)
Alarm Output Relay: Can be configured to be activated, deactivated or pulsed on user-defined sensor alarms. The relay can be configured as normally open or normally closed, and is rated for 30 V and 1 amp max.
Expansion Slot: One expansion slot is available for factory-installed expansion port.
Local Communication: Full Speed USB via USB mini-B connector
Size: 17.8 H x 11.7 D x 19.3 W cm (7.0 H x 4 .6 D x 7.6 W inches)
Weight: 2 kg (4 lbs 10 oz)
Materials: Outer Enclosure: ABS blend with stainless steel hinge pins and bronze inserts
Inner Enclosure: Polycarbonate with bronze inserts
U-Bolts: Steel with zinc dichromate finish
Gaskets: Silicone rubber
Cable entry channel: EPDM rubber
Cable entry bars: Aluminum with ABS plastic thumb screws
Data Storage Memory: Nonvolatile flash data storage, 512K bytes local storage
Memory Modes: Stop when full, wrap around when full
Operational Indicators: Up to six (depending upon options) status lights provide basic diagnostics
Logging Interval: 1 second to 18 hours, user-specified interval
Battery Type: 4 Volt, 4.5 AHr or 10 AHr, Rechargeable sealed lead-acid
Rechargeable Battery Service Life: Typical 3–5 years depending upon conditions of use. Operation within the extended operating range (but outside the normal range) will reduce battery service life.
Time Accuracy: 0 to 2 seconds for the first data point and ±5 seconds per week at 25°C (77°F)
Environmental Rating: Weatherproof enclosure, tested to NEMA 6. (Requires proper installation of cable channel system)
Mounting: 3.8 cm (1.5 inch) mast or wall mount
Enclosure Access: Hinged door secured by two latches with eyelets for securing with user-supplied padlocks
Sensor Network Cable Length: 100 m (328 ft) maximum
External Power: External power is required. The system optionally accepts the following Onset solar panels:
- SOLAR-1.2W
- SOLAR-3W
- SOLAR-6W
Alternatively it accepts an AC power adapter:
- AC-U30
Optional Analog Sensor Port Specifications
Input Channels: Two, single-ended
Field Wiring: Two- or three-wire via screw terminals on detachable connector, 16–24 AWG.
Replacement detachable connectors: Part of spares kit, Part No. A-FS-CVIA-7P-1
Input Range: User-configurable: 0–20 mA DC, 0-2.5 VDC, 0-5 VDC, 0-10 VDC, or 0–20 VDC
Minimum / Maximum Input Voltage: 0 / 24 VDC
Minimum / Maximum Input Current: 0 / 24 mA DC
Minimum Current Source Impedance: > 20 KΩ
Accuracy: ± 0.25% of FSR from 50mV to FSV
ADC Resolution 12 bits
Excitation Power: Switched 12 VDC, up to 50 mA; user-selectable warm-up from 5msec to 2 minutes
Compatible Items
This option is chosen during U30 system configuration. Recommended as primary analog sensor input.
This option is chosen during U30 system configuration. Recommended as primary analog sensor input.
This option is chosen during U30 system configuration. Recommended as primary analog sensor input.
This option is chosen during U30 system configuration. Recommended as primary analog sensor input.
This option is chosen during U30 system configuration. Recommended as primary analog sensor input.
This option is chosen during U30 system configuration. Recommended as primary analog sensor input.
This option is chosen during U30 system configuration. Recommended as primary analog sensor input.
This option is chosen during U30 system configuration. Recommended as primary analog sensor input.
This option is chosen during U30 system configuration. Recommended as primary analog sensor input.
This option is chosen during U30 system configuration. Recommended as primary analog sensor input.
Configure Logger/Power/Software
Configure your U30-NRC below: (NOTE: U30s are built to order - a minimum one week lead time is required. International customer configurations will be forwarded to your local dealer upon checkout for fulfillment - check our international dealer locator to determine if you have a dealer in your country.)Documentation
Derived Channels - - - Use this Excel spreadsheet to get the derived channels VARh, Ah & Wh from the T-VER-E50B2 power meter. Paste the data from HOBOware or HOBOlink into this spreadsheet to then calculate VAR, VA, V, PF, W, A, kWh and kW. For use with the H22-001, ZW-005, ZW-008, or U30 data loggers when using the T-VER-E50B2 power meter.
Resources
The following are associated resources for this product. In general users of this product can gain insight into its possible use by utilizing the resources below.
| White Papers: |
| Live Systems: |
| Additional Related Content: |