100 Amp Accu-CT Split-Core Current Transformer 333mV Sensor - T-ACT-0750-100

0.78”(20mm) Opening
100 Amp Accu-CT Split-Core Current Transformer 333mV

The Accu-CT split-core current transformer offers outstanding accuracy and one-handed operation.

Environment:
The T-ACT-0750-100 Sensor is for use in Indoor environments

Measurements:
The T-ACT-0750-100 Sensor supports the following measurements:
AC Current • Amps (A)
100 Amp Accu-CT Split-Core Current Transformer 333mV

The Accu-CT split-core current transformer offers outstanding accuracy and one-handed operation.

Environment:
The T-ACT-0750-100 Sensor is for use in Indoor environments

Measurements:
The T-ACT-0750-100 Sensor supports the following measurements:
AC Current • Amps (A)
  • Unprecedented Linearity
  • Window Opening 0.75 Inch
  • The Accu-CT revenue grade, split-core current transformer offers outstanding linearity and phase angle accuracy with a unique one-handed opening and closing mechanism.
  • Safe: burden resistor built-in, 333 mVac voltage output at rated full scale current, no shorting blocks needed
  • IEEE C57.13 and IEC 60044-1 accuracy: over full temperature range and down to 1% of rated current
  • Exceptionally low phase angle error: essential for accurate power and energy measurements
  • Glove-friendly: easy to open and install with one hand while wearing safety gloves
  • Approvals: UL recognized, CE mark, RoHS

To see the full specifications for this product, please see our product manual found under the documentation tab.

Accuracy: ±0.75% from 1% to 120% of rated primary current

Phase angle: ±0.5 degrees (30 minutes) from 1% to 120% of rated current

Accuracy standards: IEEE C57.13 class 1.2 and IEC 60044-1 class 1.0

Primary rating: 5 to 250 Amps, 600 Vac, 60 Hz nominal

Output: 333.33 mVac at rated current

Operating temperature: -30°C to 55°C

Safe: integral burden resistor, no shorting block needed, unlessotherwise noted

Standard lead length: 8 ft (2.4 m), 18 AWG

UL recognized, CE mark, RoHS

Assembled in USA: qualified under Buy American provision in ARRA of 2009

Compatible Loggers
USB - w/external sensor
HOBO U30-NRC Weather Station Starter Kit
This product is discontinued.
USB Data Loggers - requires external sensor
Micro Station
$231
U30 USB Weather Station
Starting at $418
Energy
$364
State
$92
Extended Memory State
$121
Web-based Monitoring Systems - via remote communication
U30 Cellular
This item is discontinued.
The upgrade for this product is the RX3000
U30 Wi-Fi
This item is discontinued.
The upgrade for this product is the RX3000
U30 Ethernet
This item is discontinued.
The upgrade for this product is the RX3000
RX3000 Remote Monitoring Station

Starting at $899
Configure & Buy

Wireless Data Nodes - via receiver/USB
Four-Channel Data Node
$329
Four External Channel Data Node
$241
Documentation for the T-ACT-0750-100

 
17053-T-ACT-0750-Manual logo
Continental Control Systems (CCS) ACT Series Split-Core Current Transformer (CT) Connection Instructions


The following are associated resources for this product. In general users of this product can gain insight into its possible use by utilizing the resources below.