Onset

 Subscribe

 
SOFTWARE UPDATES INTERNATIONAL DEALER LOCATOR CAREERS
flag English
     

U12-013

HOBO® Temperature/RH/2 External Channel Data Logger
 
Quantity
1-9
10-99
100+
$US
$125
$116
$106

Note: A complete system requires a logger and software. Sold Separately.


Overview

The HOBO U12 Temp/RH/2 External Logger contains internal sensors for monitoring two common indoor parameters. Two external channels accept a wide range of external sensors, including temperature, AC current, AC voltage, CO2, 4-20mA, and DC voltage cables.

divider
Features:
  • 12-bit resolution provides high accuracy
  • Large memory for long-term deployments or fast sampling
  • Five models to choose from, with flexible measurement options
  • Programmable and push button start
divider
Environment: Indoor
Measurement: AC Current
Temperature
Relative Humidity
DC Voltage
4-20mA
AC Voltage
Carbon Dioxide
   
 
Product ID: U12-013
Product Name: Temperature/RH/2 External Channel
Product Type: Data Loggers

Specs

Measurement range:
Temperature: -20° to 70°C (-4° to 158°F)
RH: 5% to 95% RH
External input channels (see sensor manual): 0 to 2.5 DC Volts

Accuracy:
Temperature: ± 0.35°C from 0° to 50°C (± 0.63°F from 32° to 122°F), see Plot A
RH: ± 2.5% from 10 to 90%, see Plot B; conditions above 80% RH and 60°C (140°F) may cause additional error
External input channels (see sensor manual): ± 2 mV ± 2.5% of absolute reading

Resolution:
Temperature: 0.03°C at 25°C (0.05°F at 77°F), see Plot A
RH: 0.03% RH

Drift:
Temperature: 0.1°C/year (0.2°F/year)
RH: <1% per year typical; RH hysteresis 1%

Time accuracy:
± 1 minute per month at 25°C (77°F), see Plot C
Response time in airflow of 1 m/s (2.2 mph)
Temperature: 6 minutes, typical to 90%
RH: 1 minute, typical to 90%

Operating temperature:
Logging: -20° to 70°C (-4° to 158°F)
Launch/readout: 0° to 50°C (32° to 122°F), per USB specification

Battery life:
1 year typical use

Memory:
64K bytes (43,000 12-bit measurements)

Weight:
46 g (1.6 oz)

Dimensions:
58 x 74 x 22 mm (2.3 x 2.9 x 0.9 inches)

CE The CE Marking identifies this product as complying with all relevant directives in the European Union (EU).

Plot A
Plot B
Plot A
Plot B
Plot C
Plot C

Required Items

  • 12-bit resolution provides high accuracy
  • Large memory for long-term deployments or fast sampling
  • Five models to choose from, with flexible measurement options
  • Programmable and push button start

1 Compatible Sensors

  Measurement Part #/Name
Compatible Sensors for the U12-013 
Temperature ->
TMCXXXXX
   
Part #/Name Photo Pricing Buy
TMC1-HD
Air/Water/Soil Temp Sensor (1' cable)
No Image
Qty
1-9
10-99
100+
$US
$28
$26
$24
 
TMC20-HD
Air/Water/Soil Temp Sensor (20' cable)
Qty
1-9
10-99
100+
$US
$35
$32
$30
 
TMC50-HD
Air/Water/Soil Temp Sensor (50' cable)
Qty
1-9
10-99
100+
$US
$40
$37
$34
 
TMC6-HC
Stainless Steel Temp Probe (6' cable)
Qty
1-9
10-99
100+
$US
$75
$69
$64
 
TMC6-HD
Air/Water/Soil Temp Sensor (6' cable)
Qty
1-9
10-99
100+
$US
$30
$28
$26
 

CLOSE   
 
   
Carbon Dioxide ->
TEL-7001
   
Part #/Name Photo Pricing Buy
TEL-7001
Telaire 7001 CO2 Sensor
Qty
1-9
10-99
100+
$US
$465
$430
$395
Click to view Essential Components and Accessories for the TEL-7001

   
Part #/Name Photo Pricing Buy
CABLE-CO2
CO2 Sensor to Logger Cable
Qty
1-9
10-99
100+
$US
$25
$23
$21
 
 
   

CLOSE   
 
   
AC Amperage ->
CTV-X
   
Part #/Name Photo Pricing Buy
CTV-A
0 - 20 Amp split-core AC current sensor
Qty
1-9
10-99
100+
$US
$86
$80
$73
 
CTV-B
0 - 50 Amp split-core AC current sensor
Qty
1-9
10-99
100+
$US
$86
$80
$73
 
CTV-C
0 - 100 Amp split-core AC current sensor
Qty
1-9
10-99
100+
$US
$86
$80
$73
 
CTV-D
0 - 200 Amp split-core AC current sensor
Qty
1-9
10-99
100+
$US
$109
$101
$93
 
CTV-E
0 - 600 Amp split-core AC current sensor
Qty
1-9
10-99
100+
$US
$109
$101
$93
 

CLOSE   
 
   
AC Voltage ->
T-CON-ACT-XXX
   
Part #/Name Photo Pricing Buy
T-CON-ACT-150
ConLab 0-150 Volt AC Transmitter
Qty
1-9
10-99
100+
$US
$135
$125
$115
Click to view Essential Components and Accessories for the T-CON-ACT-150

   
Part #/Name Photo Pricing Buy
Required Sensors for the T-CON-ACT-150 
CABLE-4-20MA
4-20 mA cable
Qty
1-9
10-99
100+
$US
$22
$20
$19
 
 
   
T-CON-ACT-300
ConLab 0-300 Volt AC Transmitter
Qty
1-9
10-99
100+
$US
$135
$125
$115
Click to view Essential Components and Accessories for the T-CON-ACT-300

   
Part #/Name Photo Pricing Buy
Required Sensors for the T-CON-ACT-300 
CABLE-4-20MA
4-20 mA cable
Qty
1-9
10-99
100+
$US
$22
$20
$19
 
 
   

CLOSE   
 
   
4-20 mA ->
CABLE-4-20MA
   
Part #/Name Photo Pricing Buy
CABLE-4-20MA
4-20 mA cable
Qty
1-9
10-99
100+
$US
$22
$20
$19
 

CLOSE   
 
   
DC Voltage ->
CABLE-2.5-STEREO
   
Part #/Name Photo Pricing Buy
CABLE-2.5-STEREO
Voltage Input Cable
Qty
1-9
10-99
100+
$US
$8
$7
$7
 

CLOSE   
 
   

2 Communications

  Measurement Part #/Name
Communications for the U12-013 
CABLE-USBMB
USB Cable
Qty
1-9
10-99
100+
$US
$9
$8
$7
 
U-DT-1
HOBO® U-Shuttle
Qty
1-9
10-99
100+
$US
$249
$230
$212
 
SERVER-US-4
Ethernet Server for HOBO U-series loggers
Qty
1-9
10-99
100+
$US
$145
$130
$130
 

3 Software

Required Software for the U12-013 
BHW-XXXX ->
   
Part #/Name Photo Pricing Buy
BHW-PC
HOBOware® Pro for Windows
Qty
1-9
10-99
100+
$US
$99
$92
$84
Click to view Essential Components and Accessories for the BHW-PC

   
Part #/Name Photo Pricing Buy
Accessories for the BHW-PC 
BHW-DA-GDD-CD
Growing Degree Days
Available for free download
 
BHW-DA-GPP-CD
Grains Per Pound Data Assistant
Available for free download
 
BHW-T-ALRM
Alarm and Readout Tool
Qty
1-9
10-99
100+
$US
$49
$45
$42
 
 
   
BHW-Mac
HOBOware® Pro for Mac
Qty
1-9
10-99
100+
$US
$99
$92
$84
Click to view Essential Components and Accessories for the BHW-Mac

   
Part #/Name Photo Pricing Buy
Accessories for the BHW-Mac 
BHW-DA-GDD-CD
Growing Degree Days
Available for free download
 
BHW-DA-GPP-CD
Grains Per Pound Data Assistant
Available for free download
 
BHW-T-ALRM
Alarm and Readout Tool
Qty
1-9
10-99
100+
$US
$49
$45
$42
 
 
   
BHW-LITE
HOBOware® Lite
Qty
1-9
10-99
100+
$US
$39
$36
$33
 

CLOSE   
 
   

Accessories

Part #/Name Photo Pricing Buy
Accessories for the U12-013 
HRB-TEMP
Replacement batteries for several loggers (Box of 6)
Qty
1-9
10-99
100+
$US
$14
$13
$12
 
NIST-XXXXXXXXXX ->
   
Part #/Name Photo Pricing Buy
NIST-SETUP
Setup Charge for NIST
Qty
1-9
10-99
100+
$US
$30
$30
$30
 

CLOSE   
 
   

Support

Manual

Part Number Image Name Manuals
U12-013 C MAN U12 013 PDF

Maintenance

  No maintenance items for this product

FAQs

What should I do if the logger's internal board gets wet? [show/hide]

If possible, remove the board from the case and the battery from the board. Dry the board completely using a hair dryer. If the board was exposed to salt water, rinse the board with fresh water and then dry the board. You may try inserting a new battery and downloading the data. If you are unable to access the data, or see any sign of corrosion or tarnishing on the board, contact the place of purchase for a return number. The data may be retrievable, and the logger may be repairable. Charges will apply and are dependent on the amount of damage.

I just bought a Data Logger. When I first plugged them into the USB port, a popup menu for Digital Signature concerning Microsoft asked if I wanted to continue: YES or NO. I said YES to all but one of them and now the computer won't recognize the logger. [show/hide]

Open HOBOWare, plug the logger back in, then click on Start->Settings->Control Panel->System. Click on Hardware->Device Manager and look for the logger listed under: Other Devices or Human Interface Devices — there could be a minus sign beside one of the categories or a yellow exclamation point through the device. The description listed should indicate if it is a HOBO or not. If it is not a HOBO, do not uninstall it, as it may be another USB device. Delete the "other device," then unplug the logger, wait 15 seconds and plug it back in.

Can the data be retrieved from a logger that is not communicating, or a logger that was accidentally re-launched prior to the data being downloaded? [show/hide]

There are two common reasons for data loss:

  1. Relaunching a logger before the data has been saved
  2. Technical problem with the logger itself.

 

The following section discusses data loss and its causes; it also discusses methods of retrieving lost data, and how to insure against data-loss problems.