Product Image Viewer
˂
  • T-WNB-3Y-208
˃

WattNode 208/240 VAC 1,2, or 3 Phase Wye kWh Transducer Sensor

Part # T-WNB-3Y-208
 
 

Overview

The WattNode provides accurate measurement at low cost to meet your needs for sub-metering, net-metering, energy management, and performance contracting applications. This WattNode Wye-connection kWh Transducer works with Magnelab AC Current Transformers and a Pulse Input Adapter to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms. Because these sensors tie directly into the line, they should be used only by qualified personnel.This model supports a 1,2, or 3-phase wye-connection of 208/240 VAC.

Highlighted Features

  • Measures 1, 2, or 3 phases in 2, 3, or 4 wire configurations.
  • Use with wide choice of CTs (sold separately),ratings from 5 to 1500 amps.
  • Accurate measurement of 1-,2-, or 3-phase configurations.
  • Easy to install and wire.
  • Pulse output - Compatible with pulse input logger models.
  • Small size - Can be installed in existing service panels or junction boxes.
  • Diagnostic LEDs – Confirms proper installation for all phases.
  • Bidirectional metering – Net metering for PV (photovoltaic) solar and wind power generation with only one meter.
  • Metering of variable frequency drives.
  • Line powered - No external supply required.
  • Detachable terminal blocks - Easy to install and remove.
  • UL, cUL Listed - Designed and tested for safety and use throughout North America.
  • CE Mark – Can be installed throughout the EU.

In what environment does this sensor operate?

This sensor operates in an indoor environment.

What measurements does this sensor support?

The T-WNB-3Y-208 sensor supports the following measurement: Kilowatt Hours (kWh)

The WattNode provides accurate measurement at low cost to meet your needs for sub-metering, net-metering, energy management, and performance contracting applications. This WattNode Wye-connection kWh Transducer works with Magnelab AC Current Transformers and a Pulse Input Adapter to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms. Because these sensors tie directly into the line, they should be used only by qualified personnel.This model supports a 1,2, or 3-phase wye-connection of 208/240 VAC.

Highlighted Features

  • Measures 1, 2, or 3 phases in 2, 3, or 4 wire configurations.
  • Use with wide choice of CTs (sold separately),ratings from 5 to 1500 amps.
  • Accurate measurement of 1-,2-, or 3-phase configurations.
  • Easy to install and wire.
  • Pulse output - Compatible with pulse input logger models.
  • Small size - Can be installed in existing service panels or junction boxes.
  • Diagnostic LEDs – Confirms proper installation for all phases.
  • Bidirectional metering – Net metering for PV (photovoltaic) solar and wind power generation with only one meter.
  • Metering of variable frequency drives.
  • Line powered - No external supply required.
  • Detachable terminal blocks - Easy to install and remove.
  • UL, cUL Listed - Designed and tested for safety and use throughout North America.
  • CE Mark – Can be installed throughout the EU.

In what environment does this sensor operate?

This sensor operates in an indoor environment.

What measurements does this sensor support?

The T-WNB-3Y-208 sensor supports the following measurement: Kilowatt Hours (kWh)

The country of origin for this product is the United States. To see the full specifications for this product, please see our product manual found under the documentation tab if available.

Operating: voltage range: ±20% of nominal
Frequency: 60 Hz
CT input: 0-0.5 VAC operating, 3 VAC maximum
Connectors: UL, CSA recognized, detachable screw terminals (14 AWG), 600V
Operating temp range: -30 to 60°C (-22 to 140°F)
Operating humidity range: 0 to 90% RH, non-condensing
Dimensions: 8.5 cm x 14.3 cm x 3.8 cm (3.3 in. x 5.6 in. x 1.5 in.)
Weight: 295 g (10.4 oz.)
Number of data channels: 2

To download the manual from Continental Control Systems LLC click here.

Click here to view a typical installation

Wye configuration ranges: 120, 208, 240 Volts AC
1 Phase 2 Wire 120V (with neutral)
1 Phase 3 Wire 120V/240V
3 Phase 4 Wire 120V/208V
Accuracy: ±0.45% of reading + 0.05% FS through 25th harmonic
(dependent on CT used and line variation accuracy could be 1.5% to 4% of reading)

Customers Also Bought

CASE-PELICAN-1510

The largest, most durable airline-legal carry-on available, the new 1510 Pelican case provides safe and convenient transport of your HOBO data logging equipment. This watertight, crush-proof, and dust-proof case features a sturdy but lightweight design that includes a Pick N Pluck™ foam interior, 17” retracting extension handle, strong polyurethane wheels, stainless steel hardware, padlock protectors, and a lifetime guarantee of excellence.