FlexSmart TRMS Module (2 channels) w/modular plug Sensor
S-FS-TRMSA-D FlexSmart TRMS Module (2 channels) w/modular plug Sensor
˂
  • S-FS-TRMSA-D Image 1
˃
Part # S-FS-TRMSA-D

FlexSmart TRMS Module (2 channels) w/modular plug Sensor

 

Overview

Product Description 

The 15-bit two-channel FlexSmart True RMS Current / Voltage Module accepts an input range of 5mV to 512mV and is compatible with 333mV FS output sensors. Field wiring is 2-wire via screw terminals.

IMPORTANT NOTES:

  • If using the S‐FS‐TRMSA‐D with a U30‐GSM or RX3003-00-01, RX3004 or RX2100, the S‐FS‐TRMSA‐D should be located approximately 1 meter (3 ft) from the cellular station to avoid interference from the GSM radio. Use Smart Sensor extension cable Onset part # S‐EXT‐M002.
  • If using the S‐FS‐TRMSA‐D with a RX2100 or RX3004 and you are using both the TRMSA-D modules and smart sensors, then you are limited to a maximum of 2 TRMSA-D and any combination of smart sensors to reach a total of 13 data channels.  For example, if there are two (2) TRMSA-D modules (4 data channels) in use with the RX3000 or RX2100 station, then this will leave nine (9) additional data channels for smart sensors.
Highlighted Features 
  • 2 input channels of AC Current and/or Voltage
  • Measures True RMS for accurate readings of sinusoidal and non-sinusoidal waveforms

In what environment does this sensor operate?

This sensor operates in an indoor environment.

What measurements does this sensor support?

The S-FS-TRMSA-D sensor supports the following measurements: AC Current and AC Voltage

The country of origin for this product is the United States. To see the full specifications for this product, please see our product manual found under the documentation tab if available.

Input Channels Two; AC-coupled
Field Wiring Two-wire via screw terminals on detachable connector, 16-24 AWG
Replacement detachable connectors: Part of spares kit (A-FS-TRMSA-4P-1)
Input Range 5 to 512 mVRMS
Minimum Input Voltage 5mVRMS; Input voltages < 5mV will be clipped to zero (see graph below)
Maximum Input Voltage ±1V referred to AC- terminals (pins 2 and 4)
Input Frequency 50/60 Hz
Accuracy ±0.3% of reading +/- 0.5% of FSR
ADC Resolution 15 bits
AC Waveform <4 Crest Factor
Power Requirements +3.3V @ 3mA active, 6A sleep
Transfer Function
Measurement Averaging Option Yes
CE Compliant The CE Marking identifies this product as complying with all relevant directives in the European Union (EU).

Minimum Input Voltage Graph

Customers Also Bought

CASE-PELICAN-1510

The largest, most durable airline-legal carry-on available, the new 1510 Pelican case provides safe and convenient transport of your HOBO data logging equipment. This watertight, crush-proof, and dust-proof case features a sturdy but lightweight design that includes a Pick N Pluck™ foam interior, 17” retracting extension handle, strong polyurethane wheels, stainless steel hardware, padlock protectors, and a lifetime guarantee of excellence.