EG4130 Pro - 30 Input Meter Data Logger
Limited quantities. Call for availability 1-800-564-4377.
Overview
The EG4130 Pro combines an energy meter, data logger, and a web server. This powerful combination lets you measure, store and retrieve (V, A, VAr, kWh, etc.) data directly from the device or from a remote location via the internet. You can view historical and live data for the lifetime of the hardware with the unit's convenient user interface (UI). Users have access to real-time values, long-term reports, an interactive graphical interface, and many other tools.
- 30 sensor inputs
- Supports wide range of current transformers (CTs) to accommodate virtually any size load
- Built-in web server and graphical monitoring software
- Custom view and alerts; CSV exports of granular data
- Fully web-configurable
- Built-in solid-state memory
- No service contracts
- No batteries
In what environment does this data logger operate?
This data logger operates in an indoor environment.
What measurements does this data logger support?
The EG4130 data logger supports the following measurements: AC Current, AC Voltage, Amps (A), Kilowatt Hours (kWh), Kilowatts (kW), Volt-Amp Reactive, Volt-Amp Reactive hour, Watt Hours (Wh) and Watts (W)
The country of origin for this product is the United States. To see the full specifications for this product, please see our product manual found under the documentation tab if available.
Measurement | |
AC Voltage: | L1: 85-277 Vrms L2: 0-277 Vrms L3: 0-277 Vrms |
DC Voltage: | 42 Vrms Power: 9-60 Vdc Measurement: +/-60 Vdc |
Current: | 30 channels 5-6900A max per channel Fully isolated inputs |
Frequency: | 50 or 60 Hz |
Logging Values: | V, A, W, Wh, Hz, VA, VAr, THD, deg |
Power Draw: | 12W max, 2W typical |
Environmental | |
Op. Temperature: | -30 to 70 deg C (-22 to 158 F) |
Max Altitude: | 4000m (13,123ft) |
Max Humidity: | 80% up to 31 deg C |
Meas. Category: | Overvoltage Category III |
Location: | Open type indoor device |
Pollution Degree: | 2 |
Data Logger Capacity | |
Register Count: | 64 (data storage points) |
Granularity: |
1 hour/1 second 1 year/1 minute 10 yrs/15 minute Device Lifetime/1 Day |
Safety and Regulatory | |
Safety: | IEC/UL 61010-1 Ed. 3.0 B:2010 |
CE: | IEC 61000-6-1 Ed. 3.0 B:2016 IEC 61000-6-3 Ed. 2.1 B:2011 |
FCC: | FCC Title 47 CFR Part 15-Subpart B Class B ICES-003 Information Technology Equipment Class B |
Communication | |
Homeplug AV: | Compatible with Homeplug AV- adapter within ~100ft. on same phase as L1 |
Ethernet: | IEEE 802.3 - LAN |
User Interface | |
Compatible Browsers: (Only up-to-date versions supported) |
Google Chrome Firefox Safari Internet Explorer |
Enclosure | |
Material: | FRABS |
Dimensions: | 17 x 8 x 4.6cm |
(6.7 x 3.15 x 1.81in) | |
Weight: | 300g (0.66lbs) |
Warranty Standard: | 2 years |

The following are associated resources for this product. In general users of this product can gain insight into its possible use by utilizing the resources below.
Customers Also Bought
Rope CTs are excellent for bus-bars and large switch-gear applications. Self-powered rope CTs are flexible and easy to install, but will not be accurate below 30A. Each CT includes the two-pin CT connector plug.
Technical Specifications
- 333 mVrms at rated output
- Accurate within 1% from 30A to stated current rating
- 6' twisted pair lead with CT connector
- Wide current input range from 5A - 50,000A AC
- Note: 30A minimum current required at all times. No external integrator required
Split-core CTs from J&D Sensing offer a well constructed hinged body and are accurate to +/-1% from 1%-100% of their stated current rating. The small interval for physical size options (10mm/0.39", 24mm/0.94", and 36mm/1.42") allow for a flexible installation. Each CT size has a hinge and clipping mechanism, making it easy to close the CT in tight situations.
Recently Viewed

Detailed Specifications
EG4130 Pro - 30 Input Meter Data Logger
Measurement | |
AC Voltage: | L1: 85-277 Vrms L2: 0-277 Vrms L3: 0-277 Vrms |
DC Voltage: | 42 Vrms Power: 9-60 Vdc Measurement: +/-60 Vdc |
Current: | 30 channels 5-6900A max per channel Fully isolated inputs |
Frequency: | 50 or 60 Hz |
Logging Values: | V, A, W, Wh, Hz, VA, VAr, THD, deg |
Power Draw: | 12W max, 2W typical |
Environmental | |
Op. Temperature: | -30 to 70 deg C (-22 to 158 F) |
Max Altitude: | 4000m (13,123ft) |
Max Humidity: | 80% up to 31 deg C |
Meas. Category: | Overvoltage Category III |
Location: | Open type indoor device |
Pollution Degree: | 2 |
Data Logger Capacity | |
Register Count: | 64 (data storage points) |
Granularity: |
1 hour/1 second 1 year/1 minute 10 yrs/15 minute Device Lifetime/1 Day |
Safety and Regulatory | |
Safety: | IEC/UL 61010-1 Ed. 3.0 B:2010 |
CE: | IEC 61000-6-1 Ed. 3.0 B:2016 IEC 61000-6-3 Ed. 2.1 B:2011 |
FCC: | FCC Title 47 CFR Part 15-Subpart B Class B ICES-003 Information Technology Equipment Class B |
Communication | |
Homeplug AV: | Compatible with Homeplug AV- adapter within ~100ft. on same phase as L1 |
Ethernet: | IEEE 802.3 - LAN |
User Interface | |
Compatible Browsers: (Only up-to-date versions supported) |
Google Chrome Firefox Safari Internet Explorer |
Enclosure | |
Material: | FRABS |
Dimensions: | 17 x 8 x 4.6cm |
(6.7 x 3.15 x 1.81in) | |
Weight: | 300g (0.66lbs) |
Warranty Standard: | 2 years |