The Alarms software is not sending notifications at the right time.


The Alarms software is not sending notifications at the right time.
faqid: 
216

If you have several loggers in your alarm configuration with similar and/or short polling intervals, it is possible that the monitor will try to start polling loggers that are still being accessed by the previous polling interval. Since only one polling cycle can occur at a time, any polling cycle that attempts to start before the previous cycle has completed, will be skipped.

You will know this may be occurring if you have missed a notification or received a delayed notification. (Note: a delayed notification means a notification that has a delayed date and time in the notification text. It does not mean a notification that has an accurate date and time in the notification text that was received after a delay due to SMTP or service provider delays.) It is most likely easiest to determine that you have missed or received a delayed notification by looking in the notification log text file, NotificationLog.txt,