CTV-E
0 - 600 Amp split-core AC current sensor
OverviewA split-core AC current sensor responsive over the range of 0 to 600 amps AC for use with U12 data loggers with external input channels. With an input current of AC current, sine wave, single phase 50 Hz or 60 Hz, load power factor 0.5 to 1.0 lead or lag.
This sensor is not designed for use with intrinsically-safe (IS) loggers; the molded-plastic housing is rated for indoor use per UL508, with removable leg.
Features:
- UL listed
- Sensor power induced from line voltage
- Self-gripping split-core design for fast installation
 |
| Environment: |
Indoor |
| Measurement: |
AC Current
|
| |
|
|
|
| Product ID: |
CTV-E |
| Product Name: |
0 - 600 Amp split-core AC current sensor |
| Product Type: |
Sensors |
|
Specs
- Ranges available (AC Amps): 0-20, 0-50, 0-100, 0-200, 0-600
-
- Accuracy with H8: ±5.0% of full scale
-
- Accuracy with U12: ±4.5% of full scale
-
- Response time (from 10% to 90% of amplitude): see table
-
- Input current: AC current, sine wave, single phase 50 Hz or 60 Hz, load power factor 0.5 to 1.0 lead or lag
-
- Voltage rating: 600 VAC
-
- Construction and operating environment: Molded plastic housing for indoor use per UL508; pivoting leg (leg on CTV-D and CTV-E units is fully removable); UL listed.
-
- Cable Length: 1.8m cable (6 foot)
-
- Dimensions: see table
- Notes:
- AC current sensors are not CE approved
- AC current sensors are not designed for use with Intrinsically Safe (IS) loggers
| Part No. |
Range (Amps AC) |
Approximate Response Time (milliseconds) |
Dimensions |
| Window |
Outer Length |
Outer Width |
Height |
| CTV-A |
0–20 |
440 |
2.8 cm x 2.3 cm 1.1 in. x 0.9 in. |
7.4 cm 2.9 in |
6.6 cm 2.6 in |
2.5 cm 1.0 in |
| CTV-B |
0–50 |
200 |
2.8 cm x 2.3 cm 1.1 in. x 0.9 in |
7.4 cm 2.9 in |
6.6 cm 2.6 in |
2.5 cm 1.0 in |
| CTV-C |
0–100 |
100 |
2.8 cm x 2.3 cm 1.1 in. x 0.9 in |
7.4 cm 2.9 in |
6.6 cm 2.6 in |
2.5 cm 1.0 in |
| CTV-D |
0–200 |
450 |
3.8 cm x 3.3 cm 1.5 in. x 1.3 in |
9.9 cm 3.9 in |
11.9 cm 4.7 in |
2.8 cm 1.1 in |
| CTV-E |
0–600 |
490 |
7.4 cm x 6.4 cm 2.9 in. x 2.5 in |
13.5 cm 5.3 in |
15.0 cm 5.9 in |
2.8 cm 1.1 in |
Required Items Compatible Loggers
Communications
No communications items for this product Software
No software for this product Accessories No accessories for this productSupportManual
| Part Number |
Image |
Name |
Manuals |
|
CTV-E
|
|
C CTV Manual |
PDF
|
Maintenance No maintenance items for this productFAQs| There are no FAQs for this item. |
| |
|
| |
|