HOBO ZW Series - Wireless Sensors

Applied filters:  None
NOTE: To ensure correct wireless system configuration, please consult an Onset Application Specialist before placing your HOBO ZW system order. Call 1-800-564-4377.

  • Provides centralized building performance data collection
  • Logs and wirelessly transmits real-time data within a self-healing mesh network
  • Notifies you of alarm conditions via email or text messages
  • Onboard buffer memory helps prevent data loss
  • Wide range of external sensors available
  • Powerful software for organizing and viewing data
  • AC powered with battery backup

How It Works
View HOBO ZW Series Video Overview
Results: 1 to 9 of 9


HOBO Wireless Temperature/RH Monitoring Kit - KIT-ZW-TRH
  • Supported Measurements:
    Temperature, Relative Humidity

$989
HOBO Wireless Temperature/RH Monitoring Kit - KIT-ZW-TRH



HOBO ZW-001 Temperature Data Node
  • Supported Measurements:
    Temperature
  • Range: Temp: -20° to 50° C (-4° to 122° F)
  • Accuracy: Temp: ± 0.54° C typical over 0° to 50° C (±0.97° F over 32° to 122° F)

$186
HOBO ZW-001 Temperature Data Node



HOBO ZW-003 Temperature/Relative Humidity (RH) Data Node
  • Supported Measurements:
    Temperature, Relative Humidity
  • Range: Temp: -20° to 50° C (-4° to 122° F) - RH: 5 to 95% RH
  • Accuracy: Temp: ± 0.54° C typical over 0° to 50° C (±0.97° F over 32° to 122° F) - RH: ± 2.5% from 10 to 90% typical, max. +/- 3.5%

$274
HOBO ZW-003 Temperature/Relative Humidity (RH) Data Node



HOBO ZW-005 Four-Channel Data Node
1 Temp, 1 RH, 1 Analog and 1 Pulse
  • Supported Measurements (some sensors sold separately):
    Temperature, Relative Humidity, 4-20mA, AC Current, AC Voltage, Air Velocity See more, Amp Hour (Ah), Amps (A), Carbon Dioxide, Compressed Air Flow, DC Current, DC Voltage, Differential Pressure, Gauge Pressure, Kilowatt Hours (kWh), Kilowatts (kW), Power Factor (PF), Pulse Input, Volatile Organic Compound, Volt-Amp Reactive (VAR), Volt-Amp Reactive Hour (VARh), Volt-Amps (VA), Volts (V), Water Flow, Watt Hours (Wh), Watts (W) See less
  • Range: Temperature: -40° to 70°C (-40 to 158°F) RH: 0 to 100% RH, -40° to 70°C (-40° to 158°F) Analog channel: 0 to 2.5 VDC, 0 to 5 VDC (with CABLE-ADAP5), 0 to 10 VDC (with CABLE-ADAP10), 4-20mA (with CABLE-4-20-mA)
  • Accuracy: Temperature: ±0.21°C from 0 to 50°C (±0.38°F from 32° to 122°F); see Plot A RH: ± 2.5% from 10 to 90% typical, max. ± 3.5% Analog channel: ± 1.544 mV plus 2% of reading typical
$329
HOBO ZW-005 Four-Channel Data Node



HOBO ZW-006 Four Analog Port Data Node
  • Supported Measurements (some sensors sold separately):
    Temperature, 4-20mA, AC Current, AC Voltage, Air Velocity, Carbon Dioxide See more, Compressed Air Flow, DC Current, DC Voltage, Differential Pressure, Gauge Pressure, Kilowatts (kW) See less
  • Range: Analog channels: 0 to 2.5 Vdc;0 to 5 Vdc (w/CABLE-ADAP5); 0 to 10 Vdc (w/ CABLE-ADAP10);4-20 mA (w/CABLE-4-20mA)
  • Accuracy: Analog: ± 1.544 mV plus 2 % (typical)
$241
HOBO ZW-006 Four Analog Port Data Node



HOBO ZW-007 Two External Channel Data Node
External Temp/RH and 2 Analog
  • Supported Measurements (some sensors sold separately):
    Temperature, Relative Humidity, 4-20mA, AC Current, AC Voltage, Air Velocity See more, Carbon Dioxide, Compressed Air Flow, DC Current, DC Voltage, Differential Pressure, Gauge Pressure, Kilowatts (kW), Volatile Organic Compound See less
  • Range:
    Temp: -40° to 70° C (-40° to 158° F)
    RH: 0% to 100% RH
    Analog channels: 0 to 2.5 Vdc; 0 to 5 Vdc (w/ CABLEADAP5); 0 to 10 Vdc (w/ CABLEADAP10); 4-20 mA (w/CABLE-4-20mA).
  • Accuracy:
    Temp: ± 0.21° C over 0° to 50° C (0.38° F over 32° to 122° F) - RH: ± 2.5% from 10 to 90% typical, max. ± 3.5%
    Analog: ±1.544 mV plus 2 % of reading (typical)
$329
HOBO ZW-007 Two External Channel Data Node



HOBO ZW-008 Four External Channel Data Node
External; 2 Analog and 2 Pulse
  • Supported Measurements (some sensors sold separately):
    Temperature, 4-20mA, AC Current, AC Voltage, Air Velocity, Amp Hour (Ah) See more, Amps (A), Carbon Dioxide, Compressed Air Flow, DC Current, DC Voltage, Differential Pressure, Gauge Pressure, Kilowatt Hours (kWh), Kilowatts (kW), Power Factor (PF), Pulse Input, Volatile Organic Compound, Volt-Amp Reactive (VAR), Volt-Amp Reactive Hour (VARh), Volt-Amps (VA), Volts (V), Water Flow, Watt Hours (Wh), Watts (W) See less
  • Range: Analog channels: 0 to 2.5 Vdc; 0 to 5 Vdc (w/ CABLEADAP5); 0 to 10 Vdc (w/ CABLEADAP10); 4-20 mA (w/CABLE-2.5-STEREO)
    Pulse channel: 0 to 65,535 pulses per logging interval
  • Accuracy: Analog: ± 1.544 mV plus 2% of reading (typical)
$241
HOBO ZW-008 Four External Channel Data Node


HOBO Data Receiver - ZW-RCVR
  • Range: Approx. 100 m (300 ft.) depending on obstructions or interference

$219
HOBO Data Receiver - ZW-RCVR


HOBO Data Router - ZW-ROUTER
  • Range: Approx. 100 m (300 ft.) depending on obstructions or interference

$175