HOBO State Data Logger

Part # UX90-001
 
 
$92
Add Extended Warranty for $9.20/unit?

Yes No thanks

(this choice will apply to all existing UX90-001 in your cartquote request)

HOBO data loggers requires HOBOware software (USB interface cable included w/CD purchase) and a communications device. See compatible items below.

Overview

The HOBO State/Pulse/Event/Runtime data logger records state changes,electronic pulses and mechanical or electrical contact closures from external sensing devices. This data logger is ideal for monitoring energy consumption, mechanical equipment operation, and water and gas flow. The HOBO UX90-001 State Data Logger is available in a standard 128 KB memory model (UX90-001) capable of 84,650 measurements and an expanded 512KB memory version (UX90-001M) capable of over 346,795 measurements.

Highlighted Features

  • One logger with 4 recording modes
  • Internal reed switch can be used to determine when a door or window is open or closed
  • Compatible with a wide range of external sensors
  • Ships with 2.5 mm input cable
  • Compatible with HOBOware and HOBOware Pro software for logger setup, graphing and analysis

In what environment does this data logger operate?

This data logger operates in an indoor environment.

What measurements does this data logger support?

The UX90-001 data logger supports the following measurements: Event, Kilowatt Hours (kWh), Motor On/Off, Pulse Input, Runtime, State Open/Closed and Water Flow

The HOBO State/Pulse/Event/Runtime data logger records state changes,electronic pulses and mechanical or electrical contact closures from external sensing devices. This data logger is ideal for monitoring energy consumption, mechanical equipment operation, and water and gas flow. The HOBO UX90-001 State Data Logger is available in a standard 128 KB memory model (UX90-001) capable of 84,650 measurements and an expanded 512KB memory version (UX90-001M) capable of over 346,795 measurements.

Highlighted Features

  • One logger with 4 recording modes
  • Internal reed switch can be used to determine when a door or window is open or closed
  • Compatible with a wide range of external sensors
  • Ships with 2.5 mm input cable
  • Compatible with HOBOware and HOBOware Pro software for logger setup, graphing and analysis

In what environment does this data logger operate?

This data logger operates in an indoor environment.

What measurements does this data logger support?

The UX90-001 data logger supports the following measurements: Event, Kilowatt Hours (kWh), Motor On/Off, Pulse Input, Runtime, State Open/Closed and Water Flow

The country of origin for this product is the United States. To see the full specifications for this product, please see our product manual found under the documentation tab if available.

Internal Sensor


Maximum state, event, runtime frequency: 1 Hz
Preferred switch state: No magnet present (normally open)

 

External Input


External contact input: Electronic solid state switch closure or logic driven voltage output
Range: 0 to 3 V DC (USB powered), 0 to 2.5 V DC (battery powered)
Maximum pulse frequency: 50 Hz
Maximum state, event, runtime frequency: 1 Hz
Pulse, event lockout time: 0 to 1 second in 100 ms steps
Solid state switch closure: Input Low: < 10 KΩ; Input High: > 500 KΩ
Internal weak pull-up: 100 KΩ
Input impedance: Solid state switch closure: 100 KΩ pull up

 

Logger


Resolution: Pulse: 1 pulse, Runtime: 1 second, State and Event: 1 State or Event
Logging rate: 1 second to 18 hours, 12 minutes, 15 seconds
UX90-001- - Time and Accuracy Specification ChartTime accuracy: ±1 minute per month at 25°C (77°F) (see Plot A)
Battery life: 1 year, typical with logging intervals greater than 1 minute and normally open contacts

Memory
UX90-001: 128 KB (84,650 measurements, maximum)
UX90-001M: 512 KB (346,795 measurements, maximum)

Download type: USB 2.0 interface

Download time: 10 seconds for 128 KB; 30 seconds for 512 KB

Logger Operating Range
Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing)
Launch/readout: 0° to 50°C (32° to 122°F) per USB specification

LCD: LCD is visible from: 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size: 3.66 x 5.94 x 1.52 cm (1.44 x 2.34 x 0.6 in.)
Weight: 23 g (0.81 oz)
Environmental rating: IP50

Description: ce - The CE Marking identifies this product as complying with all relevant directives in the European Union (EU)
 

Software
Graphing & Analysis
HOBOware Pro Mac/Win (USB cable included)
$99
HOBOware Pro - Mac/Win (Download Only)
$75
Compatible Sensors
Kilowatt Hours
WattNode 208/240 VAC 3-phase Delta/Wye kWh Transducer
$269
WattNode 480 VAC 3-phase Delta/Wye kWh Transducer
$269
WattNode 208/240 VAC 1,2, or 3 Phase Wye kWh Transducer
$229
Items used with above items
Voltage Input Lead Set
$75
20 Amp Accu-CT Split-Core Current Transformer 333mV
$45
50 Amp Accu-CT Split-Core Current Transformer 333mV
$45
100 Amp Accu-CT Split-Core Current Transformer 333mV
$45
250 Amp Accu-CT Split-Core Current Transformer 333mV
$45
5 AMP Mini Split-core AC Current Transformer
$35
20 AMP Mini Split-core AC Current Transformer
$35
50 AMP Mini Split-core AC Current Transformer
$35
75 AMP Mini Split-core AC Current Transformer
$35
100 AMP Split-core AC Current Transformer
$55
200 AMP Split-core AC Current Transformer
$55
600 AMP Split-core AC Current Transformer
$65
Motor On/Off
AC Current Switch
$89
Water Flow
No-lead Water Flow Meter
$207.00
Communications
Communication Cables
USB Cable
$10
Data Offload - Base Stations - Shuttles - Couplers
HOBO U-Shuttle
$281
Maintenance
Batteries
Replacement batteries (Pack of 5)
$12
Accessories
Carrying Case
Pelican Case
$245
Compliance Certificates
Compliance
$25
Documentation for the UX90-001

 
UX90-Loggers-Data-Sheet logo
UX90 Loggers Data Sheet


 
Quick Start for the HOBO® U-Series Data Logger


 
HOBO State Data Logger (UX90-001, UX90-001M) User's Manual