Play Video
Product Image Viewer
˂
  • UX120-006M
  • UX120-006M
  • UX120-006M
  • UX120-006M
  • UX120-006M
  • UX120-006M
˃

HOBO 4-Channel Analog Data Logger

Part # UX120-006M
 
 

This item ships FREE!

HOBO data loggers require HOBOware software (USB interface cable included w/CD purchase). See compatible items below.

Other Products in this Series

Overview

The HOBO UX120-006M Analog Data Logger is a high-performance, LCD display data logger for building performance monitoring applications.

As Onset’s highest-accuracy data logger, it provides twice the accuracy of previous models, a deployment-friendly LCD, and flexible support up to four external sensors for measuring temperature, current, CO2, voltage, and more.

The data logger is ideal for energy audits, building commissioning studies, equipment scheduling, and more.

Highlighted Features

  • Twice the accuracy over previous models with 16-bit resolution
  • Flexible support for a wide range of external sensors
  • LCD confirms logger operation and displays near real-time measurement data
  • Provides minimum, maximum, average and standard deviation logging options
  • On-screen alarms notify you when a sensor reading exceeds set thresholds
  • Stores 1.9 million measurements for longer deployments between offloads
  • Compatible with HOBOware and HOBOware Pro software for logger setup, graphing and analysis

In what environment does this data logger operate?

This data logger operates in an indoor environment.

What measurements does this data logger support?

The UX120-006M data logger supports the following measurements: 4-20mA, AC Current, AC Voltage, Air Velocity, Carbon Dioxide, Compressed Air Flow, DC Current, DC Voltage, Differential Pressure, Gauge Pressure, Kilowatts (kW), Temperature and Volatile Organic Comp.

The HOBO UX120-006M Analog Data Logger is a high-performance, LCD display data logger for building performance monitoring applications.

As Onset’s highest-accuracy data logger, it provides twice the accuracy of previous models, a deployment-friendly LCD, and flexible support up to four external sensors for measuring temperature, current, CO2, voltage, and more.

The data logger is ideal for energy audits, building commissioning studies, equipment scheduling, and more.

Highlighted Features

  • Twice the accuracy over previous models with 16-bit resolution
  • Flexible support for a wide range of external sensors
  • LCD confirms logger operation and displays near real-time measurement data
  • Provides minimum, maximum, average and standard deviation logging options
  • On-screen alarms notify you when a sensor reading exceeds set thresholds
  • Stores 1.9 million measurements for longer deployments between offloads
  • Compatible with HOBOware and HOBOware Pro software for logger setup, graphing and analysis

In what environment does this data logger operate?

This data logger operates in an indoor environment.

What measurements does this data logger support?

The UX120-006M data logger supports the following measurements: 4-20mA, AC Current, AC Voltage, Air Velocity, Carbon Dioxide, Compressed Air Flow, DC Current, DC Voltage, Differential Pressure, Gauge Pressure, Kilowatts (kW), Temperature and Volatile Organic Comp.

The country of origin for this product is the United States. To see the full specifications for this product, please see our product manual found under the documentation tab if available.

 

Logger w/Cable

Measurement Range:
4-20mA (w/CABLE-4-20MA) 0 to 20.1 mA
0 to 2.5 V (w/CABLE-2.5-STEREO)
0 to 5 V (w/CABLE-ADAP5)
0 to 10 V (w/ CABLE-ADAP10)
0 to 24 V (w/ CABLE-ADAP24)

UX120-006M Accuracy PlotAccuracy:
4-20mA ±0.001 mA ±0.2% of reading (w/CABLE-4-20MA)
±0.1 mV ±0.1% of reading (w/CABLE-2.5-STEREO)
±0.2 mV ±0.3% of reading (w/CABLE-ADAP5)
±0.4 mV ±0.3% of reading (w/ CABLE-ADAP10)
±1.0 mV ±0.3% of reading(w/ CABLE-ADAP24)

Resolution:
0.3 µA 4-20mA (w/CABLE-4-20MA)
40 µV (w/CABLE-2.5-STEREO)
80 µV (w/CABLE-ADAP5)
160 µV (w/ CABLE-ADAP10)
384 µV (w/ CABLE-ADAP24)

Logger

Operating range logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing);
Launch/readout: 0° to 50°C (32° to 122°F) per USB specification
Logging rate: 1 second to 18 hours, 12 minutes, 15 seconds
Logging modes: Normal, burst, or statistics
Memory modes: Wrap when full or stop when full
Start modes: Immediate, push button, date & time, or next interval
Stop modes: When memory full, push button, or date & time
Restart mode: Push button
Time accuracy: ±1 minute per month at 25°C (77°F), see Plot A
Battery life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater
Battery type: Two AAA 1.5 V alkaline batteries, user replaceable
Memory: 4 MB (1.9 million measurements, maximum)
Download type: USB 2.0 interface
Full memory download time: approximately 1.5 minutes
LCD: LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size: 10.8 x 5.41 x 2.54 cm (4.25 x 2.13 x 1 in.)
Weight: 107.5 g (3.79 oz)
Environmental rating: IP50

Description: ce - The CE Marking identifies this product as complying with all relevant directives in the European Union (EU).

x

x

x

x

1. Measurement(s)

Choose what you're measuring:


x

x

x

x

2. Sensors

Choose your sensor(s):


x

x

x

x

3. Required Items


These items are typically required with the sensors you selected. Please remove any inapplicable items that you may already own.

T-CON-ACT-150 - ConLab 0-150 Volt AC Transmitter
CABLE-4-20mA - 4 to 20 mA Input
$25
T-CON-ACT-300 - ConLab 0-300 Volt AC Transmitter
CABLE-4-20mA - 4 to 20 mA Input
$25
T-DCI-F900-L-O - Air Velocity (.15 to 5 m/s) (30 to 985 fpm)
AC-SENS-1 - AC Power Adapter for 3rd Party Sensors up to 400mA @12vdc
$29
CABLE-ADAP5 - 0 to 5 VoltsDC Voltage Input
$12
T-DCI-F900-L-P - Air Velocity (0.15 to 10 m/s) (30 to 1969 fpm)
AC-SENS-1 - AC Power Adapter for 3rd Party Sensors up to 400mA @12vdc
$29
CABLE-ADAP5 - 0 to 5 VoltsDC Voltage Input
$12
T-DCI-F900-S-O - Air Velocity (0.15 to 5 m/s) (30 to 985 fpm)
AC-SENS-1 - AC Power Adapter for 3rd Party Sensors up to 400mA @12vdc
$29
CABLE-ADAP5 - 0 to 5 VoltsDC Voltage Input
$12
T-DCI-F900-S-P - Air Velocity Sensor (0.15 to 10 m/s) (30 to 1969 fpm)
AC-SENS-1 - AC Power Adapter for 3rd Party Sensors up to 400mA @12vdc
$29
CABLE-ADAP5 - 0 to 5 VoltsDC Voltage Input
$12
TEL-7001 - Telaire 7001 CO2
CABLE-CO2 - Sensor output cable for U12 loggers
$29
T-CDI-5200-10S - Compressed Air Flow Meter - 16-200 SCFM
CABLE-4-20mA - 4 to 20 mA Input
$25
T-CDI-5400-20S - Compressed Air Flow Meter - 40-600 SCFM
CABLE-4-20mA - 4 to 20 mA Input
$25
T-VER-971BP-200 - Split-Core Bi-Polar DC Transducer
AC-SENS-1 - AC Power Adapter for 3rd Party Sensors up to 400mA @12vdc
$29
CABLE-4-20mA - 4 to 20 mA Input
$25
T-VER-PXU-L - Differential Air Pressure Transducer
AC-SENS-1 - AC Power Adapter for 3rd Party Sensors up to 400mA @12vdc
$29
CABLE-ADAP5 - 0 to 5 VoltsDC Voltage Input
$12
T-VER-PXU-X - Differential Air Pressure Transducer
AC-SENS-1 - AC Power Adapter for 3rd Party Sensors up to 400mA @12vdc
$29
CABLE-ADAP5 - 0 to 5 VoltsDC Voltage Input
$12
T-ASH-G2-100 - Ashcroft (100-psig) Gauge Pressure
AC-SENS-1 - AC Power Adapter for 3rd Party Sensors up to 400mA @12vdc
$29
CABLE-ADAP5 - 0 to 5 VoltsDC Voltage Input
$12
T-ASH-G2-200 - Ashcroft (200-psig) Gauge Pressure
AC-SENS-1 - AC Power Adapter for 3rd Party Sensors up to 400mA @12vdc
$29
CABLE-ADAP5 - 0 to 5 VoltsDC Voltage Input
$12
T-ASH-G2-500 - Ashcroft (500-psig) Gauge Pressure
AC-SENS-1 - AC Power Adapter for 3rd Party Sensors up to 400mA @12vdc
$29
CABLE-ADAP5 - 0 to 5 VoltsDC Voltage Input
$12
T-VER-8044-100 - Veris 480 V, 100 Amp Kilowatt Transducer
AC-SENS-1 - AC Power Adapter for 3rd Party Sensors up to 400mA @12vdc
$29
CABLE-4-20mA - 4 to 20 mA Input
$25
T-ION-TVOC - Volatile Organic Compound (VOC)
AC-SENS-1 - AC Power Adapter for 3rd Party Sensors up to 400mA @12vdc
$29
CABLE-4-20mA - 4 to 20 mA Input
$25

x

x

x

x

4. Software

Choose your Software:

BHW-PRO - HOBOware Software
BHW-PRO-CD - HOBOware Pro CD (USB Cable Included) Software
$99
BHW-PRO-USB - HOBOware Pro USB Drive (USB Cable Included) Software
$99
BHW-PRO-DLD - HOBOware Pro - Mac/Win (Download Only) Software
$75
HOBOware Free Download
$0
Needed for BHW-PRO-DLD and Hoboware Free Download
CABLE-USBMB - USB Cable
$10

x

x

x

x

Please review your order:

Model: UX120-006M
Step 2. Sensors (Change)
0
Step 4. Software (Change)
0

Estimated Order Total: $0

Qty:
UX120-006M configuration has been added to the cart. Click here to checkout
    • HOBO UX120-006M 4-Channel Analog Data Logger
    • Command™ strip
    • Double-sided tape
    • Hook & loop strap
    • Two AAA 1.5 V alkaline batteries

The following are associated resources for this product. In general users of this product can gain insight into its possible use by utilizing the resources below. Our user forum can also be a valuable resource for questions, use cases and general feedback. Share with us today, here!

Upcoming Webinars & Courses
Application Solutions

Customers Also Bought

CTV-B

A split-core AC current sensor responsive over the range of 5 to 50 amps AC for use with U12, UX120, and ZW data loggers with external input channels. With an input current of AC current, sine wave, single phase 50 Hz or 60 Hz, load power factor 0.5 to 1.0 lead or lag.

The molded-plastic housing is rated for indoor use per UL508.

Add to Cart
Add to Quote
Compare Product

Compare
T-ASH-G2-100

The 100-psig Ashcroft Gauge Pressure Sensor provides precision pressure measurements in compressed air systems, water, or other compatible gases and fluids with an accuracy of ±1% FS from -20° to 85°C (-4° to 185°F) and only ±1.5% FS -40° to -20°C and 85° to 125°C (-40° to –4°F and 185° to 257°F) . This sensor requires the FlexSmart Analog Module.

Requires analog port selection during U30 system configuration and use of a S-FS-CVIA when using the H22-001 data logger. When using a U12 data logger, this sensor requires an 0-5 Vdc analog input cable (CABLE-ADAP5) and external power provided by an AC adapter (AC-SENS-1).

To download additional information and manuals from Ashcroft click here.

Add to Cart
Add to Quote
Compare Product

Compare
T-VER-PXU-L

The T-VER-PXU-L is a differential air pressure transducer that utilizes a highly accurate and stable sensor, which is microprocessor profiled for improved accuracy and reliability. The stability, accuracy, and ease-of-use characteristics of the PX models make them the ideal product for differential pressure monitoring applications.

Requires analog input option during RX3000 or U30 system configuration and use of a S-FS-CVIA when using the H22-001 data logger. When using a U12 data logger, this sensor requires an 0-5 Vdc analog input cable (CABLE-ADAP5) and external power provided by an AC adapter (AC-SENS-1).

Add to Cart
Add to Quote
Compare Product

Compare
TMC6-HD

A temperature sensor for use with HOBO U-Series, UX120-006M external-channel data loggers or ZW series wireless data nodes. This model measures temperature in air, water, or soil. Accuracy and resolution vary according with attached logger model. Measurement range is -40° to 50°C (-40° to 122°F) in water or soil, -40° to 100°C (-40° to 212°F) in air; response time is minutes typical to 90% in air moving 1 m/sec (2.2 mph); response time in stirred water is 1 minute typical to 90%. This model sensor is attached to a 1.8m (6ft) cable.

Add to Cart
Add to Quote
Compare Product

Compare

Recently Viewed