Overview

This four-channel logger has internal temperature and user-replaceable RH sensors and two external channels which accept a wide range of external sensors. This model records up to 7943 measurements.

divider
Features:
  • 8-bit resolution
  • Programmable start date/time
  • Programmable sampling rate (0.5 second to 9 hours)
  • Memory modes: Stop when full or wrap-around when full
  • User-replaceable battery lasts 1 year (typical)
  • Battery level indication at launch
  • Blinking LED confirms operation
  • Non-volatile memory retains data even if battery fails
  • NIST-Traceable temperature accuracy certification available
  • Compliance certificate available
divider
Environment: Indoor
Measurement: AC Current
Temperature
Relative Humidity
DC Voltage
4-20mA
AC Voltage
Carbon Dioxide
   
 
Product ID: H08-007-02
Product Name: Temp/RH/2x External Channel
Product Type: Data Loggers

Specs

Operating range (logger): -20°C to +70°C (-4°F to +158°F), 0 - 95% RH non-condensing

Time Accuracy Full Dependence Time accuracy: approx. ±1 minute per week (±100 ppm at +20°C or +68°F),
full dependance shown in Plot A

Measurement capacity: 7944 measurements total, stored in non-volatile memory

Size: 2.4" x 1.9" x 0.8"

Weight: approximately 1 oz.

Battery: CR-2032 (lithium) user-replaceable

Battery life (continuous use): 1 year

Storage temperature: -40°C to +75°C (-40°F to +167°F)

Compatible/Req. Items

1 Compatible Sensors

  Measurement Part #/Name
Compatible Sensors for the H08-007-02 
Temperature ->
TMCXXXXX
   
 Part #/Name Photo Pricing Buy   
TMC1-HD
Air/Water/Soil Temp Sensor (1' cable)
No Image
Qty
1-9
10-99
100+
$US
$28
$26
$24
 
TMC20-HD
Air/Water/Soil Temp Sensor (20' cable)
Qty
1-9
10-99
100+
$US
$35
$32
$30
 
TMC50-HD
Air/Water/Soil Temp Sensor (50' cable)
Qty
1-9
10-99
100+
$US
$40
$37
$34
 
TMC6-HB
TMC6-HB H8 Thermistor Cable
No Image
 
TMC6-HC
Stainless Steel Temp Probe (6' cable)
Qty
1-9
10-99
100+
$US
$75
$69
$64
 
TMC6-HD
Air/Water/Soil Temp Sensor (6' cable)
Qty
1-9
10-99
100+
$US
$30
$28
$26
 

CLOSE   
 
   
AC Amperage ->
CTV-X
   
 Part #/Name Photo Pricing Buy   
CTV-A
0 - 20 Amp split-core AC current sensor
Qty
1-9
10-99
100+
$US
$86
$80
$73
 
CTV-B
0 - 50 Amp split-core AC current sensor
Qty
1-9
10-99
100+
$US
$86
$80
$73
 
CTV-C
0 - 100 Amp split-core AC current sensor
Qty
1-9
10-99
100+
$US
$86
$80
$73
 
CTV-D
0 - 200 Amp split-core AC current sensor
Qty
1-9
10-99
100+
$US
$109
$101
$93
 
CTV-E
0 - 600 Amp split-core AC current sensor
Qty
1-9
10-99
100+
$US
$109
$101
$93
 

CLOSE   
 
   
AC Voltage ->
T-CON-ACT-XXX
   
 Part #/Name Photo Pricing Buy   
T-CON-ACT-150
ConLab 0-150 Volt AC Transmitter
Qty
1-9
10-99
100+
$US
$135
$125
$115
Click to view Essential Components and Accessories for the
T-CON-ACT-150

   
 Part #/Name Photo Pricing Buy   
Required Sensors for the T-CON-ACT-150 
CABLE-4-20MA
4-20 mA cable
Qty
1-9
10-99
100+
$US
$22
$20
$19
 
 
   
T-CON-ACT-300
ConLab 0-300 Volt AC Transmitter
Qty
1-9
10-99
100+
$US
$135
$125
$115
Click to view Essential Components and Accessories for the
T-CON-ACT-300

   
 Part #/Name Photo Pricing Buy   
Required Sensors for the T-CON-ACT-300 
CABLE-4-20MA
4-20 mA cable
Qty
1-9
10-99
100+
$US
$22
$20
$19
 
 
   

CLOSE   
 
   
Carbon Dioxide ->
TEL-7001
   
 Part #/Name Photo Pricing Buy   
TEL-7001
Telaire 7001 CO2 Sensor
Qty
1-9
10-99
100+
$US
$465
$430
$395
Click to view Essential Components and Accessories for the
TEL-7001

   
 Part #/Name Photo Pricing Buy   
CABLE-CO2
CO2 Sensor to Logger Cable
Qty
1-9
10-99
100+
$US
$25
$23
$21
 
 
   

CLOSE   
 
   
4-20 mA ->
CABLE-4-20MA
   
 Part #/Name Photo Pricing Buy   
CABLE-4-20MA
4-20 mA cable
Qty
1-9
10-99
100+
$US
$22
$20
$19
 

CLOSE   
 
   
DC Voltage ->
CABLE-2.5-STEREO
   
 Part #/Name Photo Pricing Buy   
CABLE-2.5-STEREO
Voltage Input Cable
Qty
1-9
10-99
100+
$US
$8
$7
$7
 

CLOSE   
 
   

2 Communications

  Measurement Part #/Name
Communications for the H08-007-02 
CABLE-USB232
USB Serial Adapter
Qty
1-9
10-99
100+
$US
$45
$42
$38
 
H09-003-08
HOBO Shuttle data transporter
Qty
1-9
10-99
100+
$US
$179
$166
$152
 
  UP-BCP4.3-ON can not be found in the product database

Required Communications for the H08-007-02 
CABLE-PC-3.5
Interface Cable for PCs
Qty
1-9
10-99
100+
$US
$9
$8
$7
 

3 Software

Required Software for the H08-007-02 
BCXXXXXXX ->
   
 Part #/Name Photo Pricing Buy   
BCP4.3-ON
BoxCar® Pro 4.3 Starter Kit
No Image
Qty
1-9
10-99
100+
$US
$110
$102
$93
 
BC3.7
BoxCar 3.7
No Image
Qty
1-9
10-99
100+
$US
$39
$36
$33
 

CLOSE   
 
   

Acc.

Accessories for the H08-007-02 
COMPLIANCE CERT
No Image
Qty
1-9
10-99
100+
$US
$19
$19
$19
 
HRB-TEMP
Replacement batteries for several loggers (Box of 6)
Qty
1-9
10-99
100+
$US
$14
$13
$12
 

Support

Manual

Part Number Image Name Manuals
H08-007-02 G MAN HO8 PDF

Maintenance

 Part #/Name Photo Pricing Buy   
Maintenance for the H08-007-02 
HUM-UPS-500
Replacement RH sensor for HOBO H8 indoor logger only
Qty
1-9
10-99
100+
$US
$16
$15
$14
 

FAQs

How do I turn the logger off? [show/hide]

All HOBO and StowAway loggers shut off when the memory is full (unless wrap around is selected), or the data is downloaded to a computer. Once the data is downloaded to the computer, the logger is in off mode and will need to be relaunched to continue data collection. If the logger you are using is shuttle-compatible and you are downloading to a shuttle, the shuttle will automatically relaunch the logger using the previous settings.

How do I protect my loggers from electrical discharge (ESD)? [show/hide]

A discharge of static electricity may cause a running logger to stop recording. Precautions should be taken to prevent this while handling the logger.
Discharges may occur in the following situations:


When there is a charge difference between the logger and a cable being connected to it or a person touching an exposed jack.


Precautions include:

My logger only recorded one data point, stops recording immediately after launch, or stopped recording prematurely. [show/hide]

There are many situations that can cause a logger to stop recording: