HOBO® State - H06-001-02
Monitors when doors are open/closed using an internal magnetic reed switch and external magnet. External input cable included to monitor contact closures of remote devices or presence of positive DC voltage.
- Time resolution: 0.5 second
- Time accuracy: ±1 minute per week at +20°C (+68°F)
- Programmable start time/date
Environment:
The H06-001-02 Data Logger is for use in Indoor environments
Measurements:
The H06-001-02 Data Logger supports the following measurements:
Specifications
Minimum state duration: 1/2 second
Time Accuracy: ±100 ppm at 20°C,
full dependence shown in Plot A
Capacity: 2,000 state changes (requires 8K of memory in HOBO Shuttle to fully offload)
External contact input: relay switch or contact closure
Length of included external contact cable: 6'
Operating temperature: -20°C to +70°C (-4°F to +158°F)
Relative humidity range: 0 to 95%, non-condensing
Size/weight: 2.375" x 1.875" x 0.75"/approximately 1 oz.
Battery: CR-2032 (lithium); provides one year of continuous use
Storage temperature: -40°C to +75°C (-40°F to +167°F)