Pulse Data Loggers & Sensors

Applied filters:  None
Results: 1 to 16 of 16



HOBO UX90 State Logger - UX90-001
HOBO UX90 State Logger - UX90-001
  • Supported Measurements:
    Event, Kilowatt Hours (kWh), Motor On/Off, Pulse Input, Runtime, State Open/Closed, Water Flow
  • Range: Internal: Magnetic Reed Switch
    External Contact Input: Electronic solid state switch closure or logic driven voltage output
  • Replacement for: H06-001-02, U9-001

$85



HOBO UX90 State Logger - UX90-001M
Extended Memory
  • Supported Measurements:
    Event, Kilowatt Hours (kWh), Motor On/Off, Pulse Input, Runtime, State Open/Closed, Water Flow
  • Range: Internal: Magnetic Reed Switch
    External Contact Input: Electronic solid state switch closure or logic driven voltage output
  • Replacement for: H06-001-02, U9-001

$110



HOBO 4-Channel Pulse Data Logger - UX120-017
  • Supported Measurements (sensors sold separately):
    Energy: AC Current, AC Voltage, Amp Hour (Ah), kW, kWh, Power Factor (PF) See more, Pulse Input, Volatile Organic Compound (VOC), Volt-Amp Reactive (VAR), Volt-Amp Reactive Hour (VARh), Volt-Amps (VA), Volts (V), Watt Hours (Wh), Watts (W), Amps (A) See less
  • Range: 0 to 24 VDC
  • Accuracy: ± 1 minute per month at 25°C (77°F) (see Plot A in manual)

$195



HOBO 4-Channel Pulse Data Logger - UX120-017M
  • Supported Measurements (sensors sold separately):
    Energy: AC Current, AC Voltage, Amp Hour (Ah), kW, kWh, Power Factor (PF) See more, Pulse Input, Volatile Organic Compound (VOC), Volt-Amp Reactive (VAR), Volt-Amp Reactive Hour (VARh), Volt-Amps (VA), Volts (V), Watt Hours (Wh), Watts (W), Amps (A) See less
  • Range: 0 to 24 VDC
  • Accuracy: ± 1 minute per month at 25°C (77°F) (see Plot A in manual)

$295



HOBO Micro Station Data Logger - H21-002
4-external channels
  • Supported Measurements (sensors sold separately):
    Weather: Barometric Pressure, Leaf Wetness, Light Intensity, PAR, Pulse Input, Rainfall See more, Relative Humidity, Soil Moisture, Solar Radiation, Temperature, Wind Speed & Direction, 4-20mA, Voltage Input See less
    Energy: DC Voltage, kWh, Pulse Input, Relative Himidity, Temperature, Water Flow, 4-20mA
  • Range:
    -20° to 50°C (-4° to 122°F) with alkaline batteries
    -40° to 70°C (-40° to 158°F) with lithium batteries
  • Accuracy: 0 to 2 seconds for the first data point and ±5 seconds per week at 25°C (77°F)

$220



HOBO Energy Logger - H22-001
multi-channel data logger
  • Supported Measurements (sensors sold separately):
    Temperature, Relative Humidity, 4-20mA, AC Current, AC Voltage, Air Velocity See more, Amp Hour (Ah), Carbon Dioxide, Compressed Air Flow, DC Current, DC Voltage, Differential Pressure, Gauge Pressure, Kilowatt Hours (kWh), Kilowatts (kW), Power Factor (PF), Pulse Input, Volatile Organic Compound, Volt-Amp Reactive (VAR), Volt-Amp Reactive Hour (VARh), Volt-Amps (VA), Water Flow, Watt Hours (Wh), Watts (W), Wind See less
  • Range:
    -20° to 50°C (-4° to 122°F) with alkaline batteries
    -40° to 60°C (-40° to 140°F) with lithium batteries
  • Accuracy: 0 to 2 sec for the first data point and ±5 sec per week at 25°C (77°F)

$315



HOBO U30 Cellular Data Logger - U30-GSM
15 Channel Web-based Monitoring System
  • Supported Measurements (sensors sold separately):
    Weather: Barometric Pressure, Leaf Wetness, Light Intensity, PAR, Pulse Input, Rainfall See more, Relative Humidity, Soil Moisture, Solar Radiation, Temperature, Wind Speed & Direction, 4-20mA, Voltage Input See less
    Energy: AC Current, AC Voltage, Air Velocity, Amp Hour (Ah), Carbon Dioxide, Compressed Air Flow See more, DC Current, DC Voltage, Differential Pressure, Gauge Pressure, kW, kWh, Power Factor (PF), Pulse Input, Relative Himidity, Temperature, Volatile Organic Compound (VOC), Volt-Amp Reactive (VAR), Volt-Amp Reactive Hour (VARh), Volt-Amps (VA), Volts (V), Water Flow, Watt Hours (Wh), Watts (W), 4-20mA, Amps (A) See less
  • Range: -20°C to 40°C (-4°F to 104°F)
  • Accuracy: 0 to 2 seconds for the first data point
    ±5 seconds per week at 25°C (77°F)


Need Help?
Call 1-800-564-4377 or
Chat Live Now.



HOBO U30 Wi-Fi Data Logger - U30-WIF
15 Channel Web-based Monitoring System
  • Supported Measurements (sensors sold separately):
    Weather: Barometric Pressure, Leaf Wetness, Light Intensity, PAR, Pulse Input, Rainfall See more, Relative Humidity, Soil Moisture, Solar Radiation, Temperature, Wind Speed & Direction, 4-20mA, Voltage Input See less
    Energy: AC Current, AC Voltage, Air Velocity, Amp Hour (Ah), Carbon Dioxide, Compressed Air Flow See more, DC Current, DC Voltage, Differential Pressure, Gauge Pressure, kW, kWh, Power Factor (PF), Pulse Input, Relative Himidity, Temperature, Volatile Organic Compound (VOC), Volt-Amp Reactive (VAR), Volt-Amp Reactive Hour (VARh), Volt-Amps (VA), Volts (V), Water Flow, Watt Hours (Wh), Watts (W), 4-20mA, Amps (A) See less
  • Range: -20°C to 40°C (-4°F to 104°F)
  • Accuracy: 0 to 2 seconds for the first data point
    ±5 seconds per week at 25°C (77°F)


Need Help?
Call 1-800-564-4377 or
Chat Live Now.



HOBO® U30 Ethernet Data Logger - U30-ETH
15 Channel Web-based Monitoring System
  • Supported Measurements (sensors sold separately):
    Weather: Barometric Pressure, Leaf Wetness, Light Intensity, PAR, Pulse Input, Rainfall See more, Relative Humidity, Soil Moisture, Solar Radiation, Temperature, Wind Speed & Direction, 4-20mA, Voltage Input See less
    Energy: AC Current, AC Voltage, Air Velocity, Amp Hour (Ah), Carbon Dioxide, Compressed Air Flow See more, DC Current, DC Voltage, Differential Pressure, Gauge Pressure, kW, kWh, Power Factor (PF), Pulse Input, Relative Himidity, Temperature, Volatile Organic Compound (VOC), Volt-Amp Reactive (VAR), Volt-Amp Reactive Hour (VARh), Volt-Amps (VA), Volts (V), Water Flow, Watt Hours (Wh), Watts (W), 4-20mA, Amps (A) See less
  • Range: -20°C to 40°C (-4°F to 104°F)
  • Accuracy: 0 to 2 seconds for the first data point
    ±5 seconds per week at 25°C (77°F)


Need Help?
Call 1-800-564-4377 or
Chat Live Now.



HOBO U30 USB Data Logger - U30-NRC
15 Channel Energy Monitoring and Weather Station
  • Supported Measurements (sensors sold separately):
    Weather: Barometric Pressure, Leaf Wetness, Light Intensity, PAR, Pulse Input, Rainfall See more, Relative Humidity, Soil Moisture, Solar Radiation, Temperature, Wind Speed & Direction, 4-20mA, Voltage Input See less
    Energy: AC Current, AC Voltage, Air Velocity, Amp Hour (Ah), Carbon Dioxide, Compressed Air Flow See more, DC Current, DC Voltage, Differential Pressure, Gauge Pressure, kW, kWh, Power Factor (PF), Pulse Input, Relative Himidity, Temperature, Volatile Organic Compound (VOC), Volt-Amp Reactive (VAR), Volt-Amp Reactive Hour (VARh), Volt-Amps (VA), Volts (V), Water Flow, Watt Hours (Wh), Watts (W), 4-20mA, Amps (A) See less
  • Range: -20°C to 40°C (-4°F to 104°F)
  • Accuracy: 0 to 2 seconds for the first data point
    ±5 seconds per week at 25°C (77°F)


Need Help?
Call 1-800-564-4377 or
Chat Live Now.



HOBO ZW-005 Four-Channel Data Node
1 Temp, 1 RH, 1 Analog and 1 Pulse
  • Supported Measurements (some sensors sold separately):
    Temperature, Relative Humidity, 4-20mA, AC Current, AC Voltage, Air Velocity See more, Amp Hour (Ah), Amps (A), Carbon Dioxide, Compressed Air Flow, DC Current, DC Voltage, Differential Pressure, Gauge Pressure, Kilowatt Hours (kWh), Kilowatts (kW), Power Factor (PF), Pulse Input, Volatile Organic Compound, Volt-Amp Reactive (VAR), Volt-Amp Reactive Hour (VARh), Volt-Amps (VA), Volts (V), Water Flow, Watt Hours (Wh), Watts (W) See less
  • Range:
    Temp: -40° to 70° C (-40° to 158° F)
    RH: 5 to 95% RH
    Analog channels: 0 to 2.5 Vdc;0 to 5 Vdc (w/CABLE-ADAP5); 0 to 10 Vdc (w/ CABLE-ADAP10; 4-20 mA (w/CABLE-4-20mA)
    Pulse channel: 0 to 65,535 pulses per logging interval
  • Accuracy: Temp: ± 0.2° C over 0° to 50° C (0.36° F over 32° to 122° F) - RH: ± 2.5% from 10 to 90% typical, max. +/- 3.5% - Analog: +/- 1.544 mV plus 2 % (typical)

$299



HOBO ZW-008 Four External Channel Data Node
External; 2 Analog and 2 Pulse
  • Supported Measurements (some sensors sold separately):
    Temperature, 4-20mA, AC Current, AC Voltage, Air Velocity, Amp Hour (Ah) See more, Amps (A), Carbon Dioxide, Compressed Air Flow, DC Current, DC Voltage, Differential Pressure, Gauge Pressure, Kilowatt Hours (kWh), Kilowatts (kW), Power Factor (PF), Pulse Input, Volatile Organic Compound, Volt-Amp Reactive (VAR), Volt-Amp Reactive Hour (VARh), Volt-Amps (VA), Volts (V), Water Flow, Watt Hours (Wh), Watts (W) See less
  • Range: Analog channels: 0 to 2.5 Vdc; 0 to 5 Vdc (w/ CABLEADAP5); 0 to 10 Vdc (w/ CABLEADAP10); 4-20 mA (w/CABLE-2.5-STEREO)
    Pulse channel: 0 to 65,535 pulses per logging interval
  • Accuracy: Analog: ± 1.544 mV plus 2% of reading (typical)

$219



Electronic Switch Pulse Input Adapter - 1 meter Sensor - S-UCC-M001
  • Supported Measurements:
    Pulse Input
  • Range: 120 Hz (120 pulses per second)

$70



Electronic Switch Pulse Input Adapter - 6 meters Sensor - S-UCC-M006
  • Supported Measurements:
    Pulse Input
  • Range: 120 Hz (120 pulses per second)

$75



Contact Closure Pulse Input Adapter - 1 meter Sensor - S-UCD-M001
  • Supported Measurements:
    Pulse Input, Water Flow
  • Range: 2 Hz (2 pulses per second)

$70



Contact Closure Pulse Input Adapter - 6 meters Sensor - S-UCD-M006
  • Supported Measurements:
    Pulse Input, Water Flow
  • Range: 2 Hz (2 pulses per second)

$75