| |
Description |
Part Number |
Notes |
| Sensors |
| Temperature |
|
12-bit temperature, 2m cable |
S-TMB-M002 |
|
| 12-bit temperature, 6m cable |
S-TMB-M006 |
|
| 12-bit temperature, 17m cable |
S-TMB-M017 |
|
| Temperature/RH |
|
12-bit temp, 10-bit RH, 2m cable |
S-THB-M002 |
|
| 12-bit temp, 10-bit RH, 8m cable |
S-THB-M008 |
|
| Vaisala temp/RH duct-mount |
T-VAI-HMD-40Y |
requires U30 Analog Sensor Port option |
| Energy/Power |
|
WattNode kWh transducer, 208-240vac |
T-WNB-3Y-208 |
requires S-UCC-M006 and T-MAG-SCT-xxx |
| WattNode kWh transducer, 208-240vac |
T-WNB-3D-240 |
requires S-UCC-M006 and T-MAG-SCT-xxx |
| WattNode kWh transducer, 480vac |
T-WNB-3D-480 |
requires S-UCC-M006 and T-MAG-SCT-xxx |
| Veris kWh transducer, 1ph, 300A |
T-VER-8051-300 |
requires T-MAG-SCT-xxx |
| Veris kWh transducer, 3ph, 800A |
T-VER-8053-800 |
requires T-MAG-SCT-xxx |
| Veris kW transducer, 3ph, 480vac, 100A |
T-VER-8044-100 |
requires U30 Analog Sensor Port option |
| AC Current |
|
Split-core current transducer, 5A |
T-MAG-SCT-005 |
requires S-FS-TRMSA-D |
| Split-core current transducer, 20A |
T-MAG-SCT-020 |
requires S-FS-TRMSA-D |
| Split-core current transducer, 50A |
T-MAG-SCT-050 |
requires S-FS-TRMSA-D |
| Split-core current transducer, 100A |
T-MAG-SCT-100 |
requires S-FS-TRMSA-D |
| Split-core current transducer, 200A |
T-MAG-SCT-200 |
requires S-FS-TRMSA-D |
| Split-core current transducer, 600A |
T-MAG-SCT-600 |
requires S-FS-TRMSA-D |
| AC Voltage |
|
Split-core voltage transducer, 0-150vac |
T-MAG-SPT-150 |
requires S-FS-TRMSA-D |
| Split-core voltage transducer, 0-300vac |
T-MAG-SPT-300 |
requires S-FS-TRMSA-D |
| Split-core voltage transducer, 0-600vac |
T-MAG-SPT-600 |
requires S-FS-TRMSA-D |
| DC Current |
|
Split-core DC current transducer, 80A |
T-VER-H970-080 |
requires U30 Analog Sensor Port option |
| Gauge Pressure |
|
Ashcroft pressure transducer, 100 psig |
T-ASH-G2-100 |
requires U30 Analog Sensor Port option |
| Ashcroft pressure transducer, 200 psig |
T-ASH-G2-200 |
requires U30 Analog Sensor Port option |
| Ashcroft pressure transducer, 500 psig |
T-ASH-G2-500 |
requires U30 Analog Sensor Port option |
| Differential Air Pressure |
|
Setra pressure transducer, .25"WC |
T-SET-265-R25 |
requires U30 Analog Sensor Port option |
| Setra pressure transducer, 1.0"WC |
T-SET-265-001 |
requires U30 Analog Sensor Port option |
| Setra pressure transducer, 2.5"WC |
T-SET-265-2R5 |
requires U30 Analog Sensor Port option |
| Setra pressure transducer, 5.0"WC |
T-SET-265-005 |
requires U30 Analog Sensor Port option |
| Setra pressure transducer, 10.0"WC |
T-SET-265-010 |
requires U30 Analog Sensor Port option |
| Carbon Dioxide |
|
General Electric CO2 monitor |
TEL-7001 |
requires U30 Analog Sensor Port option and CABLE-2070s |
| Analog/Digital Inputs |
|
Analog Sensor Port |
Option VIA |
Provides 2 analog inputs and sensor excitation; inputs can be configured as either 0-5V or 4-20mA inputs |
| Flex Smart TRMS Module w/ Pigtail |
S-FS-TRMSA-D |
|
| Pulse Input Adapter - Electronic Switch |
S-UCC-M006 |
s |
| Pulse Input Adapter - Contact Closure |
S-UCD-M006 |
s |
| 4-20mA Input Adapter |
S-CIA-CM14 |
Use Analog Sensor Port instead; this adapter can be used when more than 2 analog inputs are needed |
| 0-5 Volt Input Adapter |
S-VIA-CM14 |
Use Analog Sensor Port instead; this adapter can be used when more than 2 analog inputs are needed |
| Accessories and Input Adapters |
|
Splitter, Smart Sensor extension, 5" |
S-ADAPT-5 |
Up to 15 smart sensors maximum |
| 5-to-10 Input Expander Kit for U30 |
S-ADAPT-X5-10 |
This is the do-it-yourself version of the U30-xxx-xxx-10-xxxx-xxx |
|
|
120V, 60Hz AC linear power supply; output is 6 Volts DC, 2 Amps. |
| AC Power Adapter |
AC-U30-EU |
AC Battery Charger for U30 - rated for 240V, 50Hz input power |
| 5m Smart Sensor Extension Cable |
S-EXT-M005 |
Up to 100 meter maximum total smart sensor cable length |
| 10m Smart Sensor Extension Cable |
S-EXT-M010 |
Up to 100 meter maximum total smart sensor cable length |
| 25m Smart Sensor Extension Cable |
S-EXT-M025 |
Up to 100 meter maximum total smart sensor cable length |
|
|
|